Sealey TP101.V2 Instructions Manual

Sealey TP101.V2 Instructions Manual

Digital diesel & fluid flow meter

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
refer to
instruction
manual
1. SAFETY
WARNING! ensure health & safety, local authority, and general workshop practice regulations are strictly adhered to when using this
equipment.
familiarise yourself with product application and limitations, as well as the specific potential hazards peculiar to this product.
9
maintain the meter in good condition (use an authorised service agent).
9
replace or repair damaged parts. use genuine parts only. non authorised parts will invalidate the warranty.
9
use only to meter diesel fuel, kerosene, petrol, water, windscreen washer or water/urea solutions.
9
ensure safety eye protection and protective clothing are worn when using this product.
9
Keep the work area clean, uncluttered and ensure there is adequate lighting.
9
maintain correct balance and footing. ensure the floor is not slippery and wear non slip shoes.
9
Keep children and unauthorised persons away from the working area.
9
After use, drain any fluids from the equipment before storage.
9
dispose of waste liquids in accordance with local authority regulations.
9
DO NOT exceed the maximum pressure of 50bar.
8
DO NOT use the equipment near open flames.
8
DO NOT smoke whilst using this equipment.
8
DO NOT use for corrosive fluids.
8
DO NOT dismantle, tamper with or adapt the equipment for any purpose other than for which it is designed.
8
DO NOT use the unit if it has been dropped or mishandled, check the unit to ensure there is no damage.
8
DO NOT use taper connections, use parallel connectors only.
8
DO NOT use compressed air on the turbine, the excessive rotation will damage the unit.
8
Keep the meter clean and store in a safe dry, childproof location.
9
WARNING! DO NOT allow uncontrolled discharge of fluids thus polluting the environment. All liquids must be disposed of according to
local authority regulations.
2. INTRODUCTION
robust rubber housing with integral digital electronic metering. easy to read large, four digit, 28mm high lcd display calibrated in litres, quarts,
pints and gallons. features flow rate indication. 1" x 1" BsP male/female fitting. Powered by 2 x AAA batteries (supplied). iP65 rated protection.
3. SpECIFICATION
model no: ...................................................................tP101.V2
flow rate: ................................................................7-120ltr/min
4. OpERATION
WARNING! DO NOT use the meter without a filter installed BEFORE the meter.
4.1.
Installation refer to fig's 1 & 3
4.1.1.
This is a bi-directional meter with 1" threaded male & female ports. The meter can be fixed in any position - fixed inline or
mobile on a control nozzle.
4.1.2.
remove the four screws (2) and separate the card housing (5) from the turbine assembly (6).
4.1.3.
Rotate the card housing in any of the four positions as shown in fig.1 and tighten the card housing with four screws (2)
© Jack sealey limited
instructions for
DIGITAL DIESEL & FLUID FLOW METER
Tp101.v2
model no:
Original Language Version
fig.1
tP101.V2 | issue:1 30/11/17

Advertisement

loading

Summary of Contents for Sealey TP101.V2

  • Page 1 Tp101.v2 model no: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Turbine Assembly: it has two threaded ports: 1 male and 1 female. it contains a turbine which turns when the media passes through it at sufficient pressure. This action generates electrical pulses which are processed by a microprocessor and the result is displayed on the lcd. Original Language Version tP101.V2 | issue:1 30/11/17 © Jack sealey limited...
  • Page 3 Reset TOTAL is replaced by TOTAL, see fig.10. Note: This situation, where only “TOTAL” is displayed, is called STANDBY mode. It remains stable until the user operates the meter again. fig.10 Original Language Version tP101.V2 | issue:1 30/11/17 © Jack sealey limited...
  • Page 4 Note: Calibration must be carried out if there is a change in any of the above operating conditions. Original Language Version tP101.V2 | issue:1 30/11/17 © Jack sealey limited...
  • Page 5 6 & 7.to calibrate the meter, the value indicated by the Batch total (example 9.800) must be forced to the Container value 9,860 marked on the graduated sample container, see fig.27. fig.27 Original Language Version tP101.V2 | issue:1 30/11/17 © Jack sealey limited...
  • Page 6 4. Press and hold reset key. “direct” appears together with the current calibration factor. An arrow appears (upwards or downwards) defining the direction (increases or decreases) of the reading, see fig.36. Original Language Version tP101.V2 | issue:1 30/11/17 © Jack sealey limited...
  • Page 7: Maintenance

    WARNING! Always make sure the liquid has been drained from the meter and that the line pressure has been released before ‰ cleaning. 5.2.4. After removing the pipes any residual elements can be removed from the turbine by simply washing it with water. Original Language Version tP101.V2 | issue:1 30/11/17 © Jack sealey limited...
  • Page 8: Troubleshooting

    5.2.2 under the Waste Batteries and Accumulators regulations 2009, Jack sealey ltd are required to inform potential purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. Jack sealey ltd Batteries Producer registration number (BPrn) is BPrn00705.