Download Print this page
Elmes Electronic U1HS Manual

Elmes Electronic U1HS Manual

One relay output remote control sets with dynamic

Advertisement

Quick Links

ONE RELAY OUTPUT REMOTE CONTROL SETS WITH
DYNAMIC CODE:
This manual covers the following remote control products operation, installation and
programming:
Equipment
Set Content
Type
U1HS
receiver U1HR + 2 transmitters UMB100HT
U1HSD
receiver U1HSR + 2 transmitters DWB100HT
U1HSL
receiver U1HR + 1 transmitter AN200HT
U1HR – receiver only
U1HR
All above listed products include the same superhet receiver model featuring:
One galvanic separated relay output with NC/NO terminals,
One OC (open collector) transistor type signal output S pulse indicating relay
output switch-over,
Two colour LED indicating state of the relay output,
Highly sensitive and selective superhet receiver,
Memory capacity of up to 112 keyfob remote control transmitters,
KEELOQ® dynamic encoding system.
Receiver Operation Modes
U1HR receiver allows various operation modes depending on selection made by jump-
ers JP1 & JP2 and programming Monostable (pulse) or Bistable (on/off) relay output
mode (step 2 and 3 of programming procedures), as shown in the Table below:
Table of relay output available operation modes
Jumpers
Monostable Mode
State
A. Pressing transmitter button sets receiver's
JP2 On
(3)
JP1
relay output on for programmed time period.
Next pressing of the button, while output is
on, prolongs set on time of the output.
JP2 Off,
C. Receiver relay output is set on for as long
JP1 On
as transmitter button is pressed and sets off,
(2)
after short delay
, on button release.
JP2 Off
D. Pressing transmitter button 1 sets the out-
JP1 Off
put on. Pressing button 2 sets output off. If
button 2 is not pressed, relay output sets off
after programmed time period
(1)
Output relay Monostable Mode (pulse) or Bistable Mode (on/off) is programmed in
steps 2 and 3 of programming procedures.
(2)
Delayed output set off reduces risk of unwanted interruptions in output set on con-
tinuity, due to interferences caused e.g. electric motors. Precise setting of this
short delay timing is facilitated by programming 8-fold longer time delay of that
needed. Example: to obtain 0.5s set off delay, programmed delay of 4..5s delay
must be made (0.5 x 8=4).
Number of remote control transmitters that can be used in this mode is limited to
20.
(3)
In modes A & B jumper JP1 selects timing of switch-over signal pulses at output S:
jumper On – 0.25s pulse, jumper Off – 0.50s pulse. Longer timing of switch-over
signal pulses is necessary for certain acoustic signalling devices in which shorter
pulses are not recognized properly.
(4)
This mode requires use of hand transmitter with two or more buttons.
KEELOQ® Encoding System
In the system, newly encoded control signal is generated and sent each time transmitter
button is pressed. Receiver monitors code changes and responds to new code signals
only. Once received code will not be accepted second time. This allows protection of
radio transmission signals from deliberate code grabbing and unauthorized use.
Transmitter Memory
As each transmitter generates specific dynamic code, receiver must "learn" and memo-
rize individual coding of every transmitter that will operate with the receiver. Therefore,
receiver's memory capacity is limited to 112 transmitters. Learning 113
would delete first transmitter in memory, etc. Eliminating lost or stolen transmitters from
receiver's memory requires deleting all transmitters and learning all remaining transmit-
ters again. Deleting single transmitter from receiver's memory is possible only with the
use of the transmitter to be deleted (see pt 5 of programming procedures).
Receiver Relay Output
Receiver is equipped with galvanic isolated relay output with NO (normally open) and
NC (normally closed) three wiring terminals – one common. The output switches over
on command received from transmitter. Details are shown on installation diagram in-
cluded in this manual.
Signalling Output S
The receiver features one open collector type (OC) signalling output for connecting to
external acoustic siren or light strobe. The output generates two pulses shorting to re-
ceiver's ground (-V) on receiver's relay set ON and one pulse on relay set OFF. Two
pulses are generated also when pressed transmitter's button is used to prolong set on
timing in monostable mode only (mode A – see Table above). In operation modes D
and E (see Table above), in which button 1 sets output on and button 2 sets output off,
two pulses are generated each time button 1 is pressed and one pulse each time button
2 is pressed.
LED Indication
Receiver is equipped with two colour LED signalling power supply connection and sta-
tus of relay output. It lights red when power is connected and relay output is not activat-
ed. When relay is set on it lights green.
Receiver Installation
Receiver's place of installation should be dry and away from electromagnetic power
lines, radio transmitters, metal screening and other devices that may cause interference
and reduce operation range. It is recommended to install the receiver well above
floor/ground level and test practical operating range of transmitter-receiver set prior to
firm installation. The level of hand transmitter signals and local unwanted radio interfer-
ence signals can be checked using optional Elmes RFM indicator.
e-mail: elmes@elmes.pl
internet: www.elmes.pl
U1HS, U1HSD, U1HSL, U1HR
Operating Range
100 m
100m
200 m
-
(1)
Bistable Mode
B. Each pressing of remote
transmitter button sets re-
ceiver relay output on and off
alternately (on/off mode).
Not available
E. Pressing transmitter button
1 sets output on. Pressing
button 2 sets output off.
(4)
th
Receiver LED low flashing green in confirms properly performed programming proce-
dure. Fast flashing LED in red indicates programming error. Programming procedure
must be repeated.
1. Learning transmitter(s) to receiver's memory (maximum 112):
a) Press receiver's PRG1 switch for less than 2 seconds - LED lights green.
b) Press shortly hand transmitter button once - receiver LED changes to red.
c) Press shortly the same hand transmitter button again.
2. Programming receiver output monostable operation mode (pulse) and output
set on timing:
a) Press receiver's PRG1 switch - LED lights green and after two seconds changes to
red. Now release the switch.
b) Press hand transmitter button. Relay in the receiver sets on. After required pulse
time has lapsed press hand transmitter button again. Relay in receiver sets off. Af-
ter 2 seconds receiver's LED starts flashing green confirming end of the procedure.
3. Programming receiver output bistable (on/off) operation mode:
a) Press receiver's PRG1 switch - LED lights green and after two seconds changes to
red. Now release the switch.
b) Press transmitter button three times with less than 2 seconds intervals. Receiver
LED flashes green confirming end of the procedure.
4. Deleting all transmitters in receiver memory:
Press and hold depressed PRG1 switch for more than 8 seconds. Receiver LED
first lights green. After 2 seconds changes to red and after 6 seconds starts flash-
ing green. Now release the switch. To learn new transmitter(s) follow procedure 1
above.
5. Deleting single transmitter in receiver memory (condition: transmitter to be de-
leted is available):
(1)
a) Press receiver's PRG1 switch for less than 2 seconds - LED lights green.
b) Press shortly button of the hand transmitter to be deleted - receiver LED changes
to red.
c) Perform one of the following steps:
 Press button of any other Elmes Electornic made hand transmitter button, or
 temporarily disconnect receiver power supply, or
 wait round 30 seconds till receiver exits programming mode.
Correct performing of this procedure is confirmed by LED flashing red (error indication).
Advice 1: Procedures 2, 3 and 5 can be performed with the use of transmitter
learned to the receiver memory.
Advice 2: Time for performing procedures 1 and 5 above is limited to 30 seconds.
If the procedures are not completed within this time period receiver exits
programming mode and error is indicated.
SPECIFICATION
UMB100HT transmitter: radiated power < 5mW, battery: 12V (23A).
AN200HT transmitter: radiated power < 10mW, battery: 9V (6F22).
Receiver:
- dynamic code system KEELOQ® of Microchip Corp. USA,
- transmitter memory capacity: 112 (up to 20 in mode C),
- superhet receiver module with sensitivity: -106 dBm,
- power supply range: 11..17VDC, 50mA.
- operating temperature range from -20 to + 55°C,
- output relay max. power rating: 1A, 120VAC/30VDC,
- monostable output mode timing: from 0,25s up to 4 hours,
- bistable output mode: on/off,
- signal output S (1A/60V max.) OC type,
- sabotage alarm terminals NC type (closed box).
- external dimensions (h/w/l): 24/46/73 mm
Low battery in transmitters is indicated either by its LED flashing (UMB100HT) or dim-
ming and failing to light (AN200HT).
Manufacturer: ELMES ELEKTRONIK, 54-611 Wroclaw, Avicenny 2, PL
tel. +48717845961, fax +48717845963
WARNING! Batteries may contain substances hazardous to human health. Do
not place batteries in fire or household waste. Dispose of old batteries properly
transmitter
in accordance with local law regulations. Used batteries can always be disposed
of at points of electronic waste collection.
Manufacturer's Limited Warranty
This product carries two year manufacturer's warranty as from the date of purchase.
The warranty is limited to the replacement of faulty original parts or repair defects of im-
proper manufacture. Damage, misuse or improper handling by the user or installer as
well as any alterations in product's hardware or software caused by unauthorized per-
son violate warranty obligations and all due repair costs will be charged.
Elmes Electronic shall not be liable for any personal or material damage or loss result-
ing from any of
its products di-
rect,
indirect
or partial use
or
failure
to
operate
properly.
IMPORTANT! Output S must not be directly connected to (+) pole of power supply (see dia-
gram above).
Wyjście S nie może być bezpośrednio łączone do (+) zasilania (patrz schemat).
UWAGA!
PROGRAMMING PROCEDURES
Elmes Elektronik 01.2015. All rights reserved

Advertisement

loading

Summary of Contents for Elmes Electronic U1HS

  • Page 1 Details are shown on installation diagram in- Elmes Electronic shall not be liable for any personal or material damage or loss result- cluded in this manual.

This manual is also suitable for:

U1hsdU1hslU1hr