Download Print this page
Sealey RE97XS05 Instructions

Sealey RE97XS05 Instructions

Short push rams

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
refer to
Wear protective
instruction
eyewear
manual
1. SAFETY
WARNING! Ensure Health & Safety, local authority and general workshop practice regulations are adhered to when using this equipment.
familiarise yourself with product application and limitations, as well as the specific hazards peculiar to the kit.
9
WARNING! disconnect the ram from the hydraulic pump before servicing or performing any maintenance on the unit.
maintain in good order. replace/repair with genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9
Keep the ram clean for best and safest performance.
9
WARNING! ensure you know how much load you are pushing. never exceed the maximum pushing capacity.
use only with sealey hydraulic pump and accessories. Wrong equipment may damage unit and invalidate your warranty.
9
We recommend the use of safety eyewear and heavy duty gloves when working with this equipment. Both are available from your authorised
9
sealey stockist.
maintain correct balance and footing. ensure the floor is not slippery and wear non-slip shoes.
9
if working on an 'off centre' load, pump with care. if you feel undue resistance, stop and re-adjust the set-up.
9
WARNING! Keep your hands, body and clothing away from the ram and load when in use. Take any necessary precautions
to protect your personal safety whilst using the ram.
Always be prepared for unexpected load movement, never place yourself or any part of your body in a position that could result
in injury, always use a crowbar or similar device to manoeuvre the load.
ensure the hydraulic hose is not bent or kinked but laid out correctly. Avoid damage to the hose (e.g. crushing/cutting).
9
Keep non-essential persons away from the operating area. Be aware of the locations of other persons assisting you.
9
When releasing tension from the load be sure to undo the hydraulic valve VerY slowly.
9
DO NOT operate the ram if any parts are damaged or missing as this may cause failure and/or personal injury.
8
WARNING! DO NOT use for any purpose other than for which it is designed.
DO NOT modify accessories for use with this ram.
8
When not in use, place dust cap in end of hydraulic connector and store the ram, in a safe, dry, childproof location.
9
WARNING! The warnings, cautions and instructions in this manual cannot cover all possible conditions and situations that
may occur. It must be understood by the operator that common sense and caution are factors which cannot be built
into this product, but must be applied by the operator.
2. INTRODUcTION
extremely short collapsed height makes these rams suitable for use where there is almost no clearance at the lift point. unique ram and cylinder
bearings absorb eccentric load stresses in order to protect the cylinder against abrasion, over-extension and jamming. chromed rams with
polyurethane seals and wipers provide longer service life. rams feature high flow quick connecting couplers with dust caps. use in conjunction
with 10t or 4t pump and hose (610/40, 610/42 or 604/40, 604/42.
3. SPEcIFIcATION
Ram Model No. Type. capacity. closed /Open Height.
re97Xs05
Push
5000kg
re97Xs10
Push
10000kg
re97Xs20
Push
20000kg
re97Xs30
Push
30000kg
4. OPERATION
o
WARNING! ensure you have read and understood
chapter 1 safety instructions.
4.1.
remove plug from ram connector (retain plug to reseal connector after use).
4.2.
connect to suitable hydraulic pump (see section 3).
4.3.
Position ram as required and operate pump.
IMPORTANT: Always store the ram with the piston fully retracted to help prevent corrosion. rams with signs of rust on the main piston
cannot be replaced under warranty.
© Jack sealey limited
instructions for
SHORT PUSH RAMS
model no's:
RE97XS05, RE97XS10, RE97XS20, RE97XS30
Wear gloves
33/39mm
43/54mm
52/63mm
59/71mm
Original Language Version
re97Xs05, re97Xs10, re97Xs20, re97Xs30 | issue3(l) 28/10/16

Advertisement

loading

Summary of Contents for Sealey RE97XS05

  • Page 1 RE97XS05, RE97XS10, RE97XS20, RE97XS30 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500. Environmental Protection Recycle unwanted materials instead of disposing of them as waste.

This manual is also suitable for:

Re97xs10Re97xs20Re97xs30