Download Print this page
Sealey RE83/840.V2 Instructions

Sealey RE83/840.V2 Instructions

Air hydraulic pump 10tonne

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INvALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
Only fully trained and qualified persons should use this equipment. These instructions are not a substitute for user receiving full
supervised training by a qualified person. It is important the user understands the applications, limitations and potential hazards
of the product.
1. SAFETY INSTRUCTIONS
WARNING! Ensure Health & Safety, local authority and general workshop practice regulations are adhered to when using this equipment.
Familiarise yourself with product application and limitations, as well as the specific hazards peculiar to the pump.
WARNING! Disconnect the hydraulic pump from the apparatus before servicing or performing any maintenance.
Maintain pump in good order. Replace/repair with genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
Use qualified person to lubricate and maintain the hydraulic pump. DO NOT use brake fluid to top up hydraulic unit. Use Sealey hydraulic oil only.
Keep the pump and treadle clean for best and safest performance.
WARNING! Ensure you know how much load you are pushing. Never exceed the maximum pushing capacity.
The kit accessories may be used with other popular makes of kit.
We recommend the use of BS approved safety impact goggles and heavy duty gloves when working with this pump. Both are available from your
authorised Sealey dealer.
Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
If working on an 'off centre' load, pump with care. If you feel undue resistance, stop and re-adjust the set-up.
Ensure any hydraulic hoses are not bent or kinked but laid out correctly. Avoid damage to hoses (e.g. crushing/cutting).
Keep non-essential persons away from the operating area. Be aware of the locations of other persons assisting you.
DO NOT operate the pump if any parts are damaged or missing as this may cause failure and/or personal injury.
WARNING! DO NOT use for any purpose other than for which it is designed.
When not in use, place dust cap in end of hydraulic hose or cylinder and store in a safe, dry, childproof location.
2.
INTRODUCTION/SPECIFICATIONS
2.1
Suitable for use with SuperSnap hydraulic ram as supplied with Model No. DZRE92/C body straightener and all body kits.
Model No. RE83/840.V2
Model No. RE83/840/CWH.V2
MODEL: RE83/840.V2
© Jack Sealey Limited
INSTRUCTIONS FOR:
AIR HYDRAULIC PUMP 10TONNE
MODEL Nos: RE83/840.v2 & RE83/840/CWH.v2
R
Air Supply
Oil Pressure
90-120psi
10000psi
90-120psi
10000psi
Original Language Version
Oil Capacity
Hose
450cc
not supplied
450cc
supplied (loose)
MODEL: RE83/840/CWH.V2
RE83/840.V2 & RE83/840/CWH.V2
Issue: 1 - 13/11/12

Advertisement

loading

Summary of Contents for Sealey RE83/840.V2

  • Page 1 Maintain pump in good order. Replace/repair with genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.  Use qualified person to lubricate and maintain the hydraulic pump. DO NOT use brake fluid to top up hydraulic unit. Use Sealey hydraulic oil only. ...
  • Page 2 3. OPERATION Setting up 3.1.1 Remove pipe plug from hydraulic adaptor and connect a hose (Model RE83/840.V2 only) 3.1.2 Remove the shipping plug from the air inlet port and insert a 1/4" NPT quick release coupler (If not fitted). 3.1.3 Connect an air supply to the quick release air hose coupler and connect the hydraulic hose to the ram or device coupler.

This manual is also suitable for:

Re83/840/cwh.v25024209143509