2. PACKACE CONTESTS ........................3 3. IMPORTANT WARNINGS ....................... 3 4. INSTALLATION ..........................4 Preparing for Use........................4 Installing microHAM USB Device Router ..................5 Installing the USB Driver......................6 Configuring the USB Codec ......................7 Creating and Using Virtual Ports ....................9 5.
If the terms of the above warranty are not acceptable, return the unit, all its associated documents and accessories in the original package, prepaid, to microHAM or to your supplier for a full refund less shipping cost.
Note: the CAT interface is not configured at the factory. 2. Plug the DB15M on the radio cable set into the DB15 connector on the rear panel of the DIGI KEYER and plug ALL connectors from the cable set to the appropriate jacks at the rear panel of your transceiver.
Installing microHAM USB Device Router To install Router click on the Install USB Device Router link on the installation CD or download the most recent installation package from the microHAM web site: www.microHAM.com/downloads.html. If you download an updated package, click on "urouter_release_xx_xx.exe"...
Ignore this message and click "Continue Anyway". If the USB driver is successfully installed, you should see a "microHAM USB Device" driver in Universal Serial Bus controllers section of Windows Device Manager without any exclamation mark.
Page 8
To configure and use DIGI KEYER with Windows based application programs it is necessary to have installed the USB driver, started the Router, and applied power to DIGI KEYER by turning on the attached radio or external power supply. Router is then configured to match the requirements of the application (logger or digital mode) software.
Options | General - Start Router Minimized: when checked, Router will started minimized Options | Digital Band Map: Customizable band boundaries for the digital modes used for automatically selecting VOICE/DIGITAL settings. The Digital Bandmap has no effect on the DIGI KEYER. Minimize: Clicking this will minimize Router to the system tray at the bottom right corner of the Windows Taskbar (the "System Notification Area").
KEYER, you may wish to customise the settings for each application. For easy switching among applications, Router supports up to 12 user definable Presets. Different DIGI KEYER configurations can be stored in these presets and recalled almost instantly simply by clicking on the preset button.
Router loads templates from the template directory – the default location is: C:\Program Files\microHAM\template. When Router loads a template, it looks for an html file with the same name as the template in the same directory. If such file is found, it is displayed. If Router fails to find an html file, it will look for a txt file with the same file name as template in same directory.
It is necessary to create several virtual serial ports (COM ports) in order for a Windows application (logging, control or digital mode program) to access microHAM devices. By using templates, the neccessary virtual ports are created automatically. However, virtual ports can also be created manually.
About - Shows the version number DEVICE CONFIGURATION TABS There are three (3) tabs for configuring DIGI KEYER. Each tab controls a part of DIGI KEYER's functions. Any change to the first two (2) tabs are applied immediately to DIGI KEYER. Changes in Messages are NOT applied automatically.
PA when the PTT channel is used for T/R switching. More information about T/R switching, DIGI KEYER PTT outputs and the sequencer is provided in chapter 15.3 Router allows assigning a virtual serial port to the PTT channel and supports PTT via DTR or RTS.
Hz sampling, a 48000 Hz sample rate in router will work best with PSKcore based programs. Generate Test Signal: causes DIGI KEYER to output a 1500 Hz audio tone for setting the transmit output level. Some tips from Geoff Anderson, G3NPA:...
PTT – T/R KEYING DIGI KEYER has three (3) PTT outputs: PTT, PA PTT and LNA PTT. PTT is brought out to the DB15 Radio Port. PA PTT and LNA PTT are available on RCA connectors at the DIGI KEYER rear panel.
. If the PTT box is checked, the characters will be transmitted. CW - test button keys the DIGI KEYER CW output. The red arrow on the Ports tab and the red CW LED on the DIGI KEYER front panel should light continuously. When the radio is in the CW mode and is manually keyed (or break-in is enabled) a continuous CW carrier will be transmitted.
DIGI KEYER is connected to the computer using a single A-B USB cable which is included. The transceiver and DIGI KEYER are connected by single radio cable terminated on one side by a DB15M and on the other side by the appropriate plugs for the specific transceiver model. The cable carries power for DIGI KEYER, audio, CAT control and keying.
• Compatible with all MS Windows based logging or control software the special microHAM "USB Device Router" program creates virtual COM ports for full operation with • standard Windows applications. customizable presets allow instantly changing DIGI KEYER parameters to match the program •...