Mantracourt T24-BSi Technical Manual

T24 series
Hide thumbs Also See for T24-BSi:
Table of Contents

Advertisement

Quick Links

T24 Technical Manual
Programming guide & advanced
documentation
User Manual
www.mantracourt.co.uk

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T24-BSi and is the answer not in the manual?

Questions and answers

Summary of Contents for Mantracourt T24-BSi

  • Page 1 T24 Technical Manual Programming guide & advanced documentation User Manual www.mantracourt.co.uk...
  • Page 2 Config ........................13 Duration ........................13 Pair Response ......................14 Packet Type ......................14 From ID ........................14 Data Tag ........................14 RSSI ........................14 CV ......................... 14 T24-BSi and T24-BSu [Base Station] ..................15 Mantracourt Electronics Limited T24 Technical Manual...
  • Page 3 Power Supply ........................38 Battery Life ........................38 See Appendix B – Acquisition Module Battery Life – Non Strain Gauge Input ......... 38 Installation ........................38 Antennas ........................38 T24-RA [Resistance (Potentiometer) Acquisition] ................. 39 Mantracourt Electronics Limited T24 Technical Manual...
  • Page 4 LED Mode Indication ......................64 Power Supply ........................64 Installation ........................64 Connections ........................65 Serial Settings ........................65 T24-AO1 [Analog Output] ....................... 66 Overview .......................... 66 Configuration ........................66 Communications ......................... 66 Parameter List ........................ 66 Mantracourt Electronics Limited T24 Technical Manual...
  • Page 5 Accurate Guide ......................91 Acquisition Module Battery Life – Non Strain Gauge Input ............92 Accurate Guide ......................92 Appendix C ......................... 94 Customising T24 Toolkit ....................... 94 Appendix D ......................... 95 Approvals ......................... 95 Mantracourt Electronics Limited T24 Technical Manual...
  • Page 6 FCC ..........................95 Industry Canada ......................... 95 OEM / Reseller Marking and Documentation Requirements ............96 FCC ........................... 96 IC ..........................96 CE ..........................96 Worldwide Regional Approvals ..................... 97 Important Note ....................... 97 Mantracourt Electronics Limited T24 Technical Manual...
  • Page 7: Introduction / Overview

    To communicate with T24 devices a base station is required. Base stations will offer RS232, RS485 and USB interfaces. Refer to the Base Station section T24-BSi and T24-BSU for details on connections and interfacing. 2.4GHz Radio General Communicating with T24 Devices To communicate with T24 devices a base station is required.
  • Page 8: Packet Type Byte

    Response Timed out. A Timeout response was not received by the device. Response Data Response – Data invalid. Invalid The device has reported that the data in a Write was invalid or out of range. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 9: Data Packet Structures

    INT32 Float String 0-64 Binary 0-64 NOTE: See Data Type Formats in Appendix A The Display As bits should be used where possible as this can help in presenting the data for display purposes. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 10: Data

    The command number of the parameter you want to write to. You will need to refer to the device manual for this information. Data Type Specify the data type of the data you are sending. Data types are as follows: Data Type Description Size In Bytes No content/unknown UINT8 UINT16 INT32 Mantracourt Electronics Limited T24 Technical Manual...
  • Page 11: Responses To Read And Write

    This indicates correlation value which equates to the quality of the signal when this packet was received. See RSSI & CV in Appendix A If the ACK is in response to a READ then it will contain data: Packet Type From ID Data Type Data RSSI […] Mantracourt Electronics Limited T24 Technical Manual...
  • Page 12: Packet Type

    This packet is returned if the device receiving the read or write does not recognize the command number. Packet Type From ID RSSI Packet Type This is 0x8 hex (8 decimal) and may have higher bits set which indicate Error, Low Battery and Broadcast. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 13: Rssi

    The pairing process is usually initiated by one device (a handheld for example or PC software using a base station) and this enters pairing master mode and is ready to pair for a user defined time period. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 14: Pair Request

    If the remote device enters its own pair mode (non master) then the communications negotiations will take place and the device may come out of any low power modes and a response will be sent to the base station. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 15: Pair Response

    This indicates correlation value which equates to the quality of the signal when this packet was received. See RSSI & CV in Appendix A NOTE: After configuration or calibration you should power cycle the paired device to return it to normal operation. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 16: T24-Bsi And T24-Bsu [Base Station]

    Addressing is vital as it is this that distinguishes between base stations. When using USB base stations you may only ever have one T24-BSu connected to a PC at any time. Using T24-BSi will allow multiple USB base stations to be connected to single PC. Unique Addresses are again required in this instance.
  • Page 17: Connection

    At any rate below 230400 is may be possible to lose packets at high data rates as the serial cannot keep pace with the radio transmissions. If USB is not selected as the interface (Switch positions 5 to 7) then this switch position selects whether the serial interface is RS232 or RS485. 232/485 RS232 RS485 Mantracourt Electronics Limited T24 Technical Manual...
  • Page 18: Interfaces

    RS485 is a bus master system and is not ideally suited to full communications with devices when multiple • devices are providing data. This is fine for the normal operation of data acquisition but it is recommended that only the device to be configured is active during configuration. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 19: Usb Communications

    Connection to the base station will be either a captive USB cable (T24-BSu) or a USB socket B for connection using a standard USB A-B cable (T24-BSi). There is an optional cable assembly for the T24-BSi to provide for a USB connection while the device is still fitted to the ABS case.
  • Page 20: Led Indication

    NOTE: If you do not want to use the Mantracourt supplied communications DLL (T24drv.dll) you may be interested in the following: We have successfully tested EasyHID which supplies the mcHID.dll which is a great generic way of connecting to HID devices.
  • Page 21: Communications

    Note after a Reset the device will be asleep. NOTE: All changes require a SAVE command to enable them to survive through power cycle or RESET command. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 22: Installation

    Installation The base T24-BSi should be mounted horizontally on a wall or ceiling so that the side face containing the PCB antenna faces the general direction of the target devices. The T24-BSu should also be positioned to present itself to the other radios in a 'landscape' aspect.
  • Page 23: T24-Sa [Strain Acquisition]

    Set or read the 2 byte Data Tag that is used when UINT16 transmitting the weight in a Data Provider Packet. Note that default value is set to last 2 bytes of ID. NumCalPoints Number of calibration points required. Range 2 to 9 UINT8 Mantracourt Electronics Limited T24 Technical Manual...
  • Page 24 Definition Turn shuntcal off Turn shuntcal on Status Live status where the bit values indicate status. The following table shows the decimal bit values and their meaning. Bit Value Definition STATUS_SHUNT_CAL STATUS_INPUT_INTEGRITY Reserved Reserved Mantracourt Electronics Limited T24 Technical Manual...
  • Page 25: Data Provider Format

    > 99 18 bits 1:250,000 > 999 18.75 bits 1:400,000 Power Supply See Appendix B – Acquisition Module Power Supply Battery Life See Appendix B – Acquisition Module Battery Life – Strain Gauge Input Mantracourt Electronics Limited T24 Technical Manual...
  • Page 26: Installation

    Installation Antennas See Appendix B – Antenna Installation Mantracourt Electronics Limited T24 Technical Manual...
  • Page 27: T24-Va [0-10V Voltage Acquisition]

    Set or read the 2 byte Data Tag that is used when UINT16 transmitting the weight in a Data Provider Packet. Note that default value is set to last 2 bytes of ID. NumCalPoints Number of calibration points required. Range 2 to 9 UINT8 Mantracourt Electronics Limited T24 Technical Manual...
  • Page 28 Bit Value Definition STATUS_SHUNT_CAL STATUS_INPUT_INTEGRITY Reserved Reserved STATUS_POWER_UP STATUS_BATT_LOW STATUS_DIGITAL_INPUT STATUS_DIGITAL_OUTPUT Reset Restarts the device and utilises new channel and Command encryption keys if those have been changed and saved. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 29: Data Provider Format

    Resolution / Bits Power Supply See Appendix B – Acquisition Module Power Supply Battery Life See Appendix B – Acquisition Module Battery Life – Non Strain Gauge Input Antennas See Appendix B – Antenna Installation Mantracourt Electronics Limited T24 Technical Manual...
  • Page 30: T24-Ia [4-20Ma Current Acquisition]

    Set or read the 2 byte Data Tag that is used when UINT16 transmitting the weight in a Data Provider Packet. Note that default value is set to last 2 bytes of ID. NumCalPoints Number of calibration points required. Range 2 to 9 UINT8 Mantracourt Electronics Limited T24 Technical Manual...
  • Page 31 Bit Value Definition STATUS_SHUNT_CAL STATUS_INPUT_INTEGRITY Reserved Reserved STATUS_POWER_UP STATUS_BATT_LOW STATUS_DIGITAL_INPUT STATUS_DIGITAL_OUTPUT Reset Restarts the device and utilises new channel and Command encryption keys if those have been changed and saved. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 32: Data Provider Format

    > 99 18 bits 1:250,000 > 999 18.75 bits 1:400,000 Power Supply See Appendix B – Acquisition Module Power Supply Battery Life See Appendix B – Acquisition Module Battery Life – Non Strain Gauge Input Mantracourt Electronics Limited T24 Technical Manual...
  • Page 33: Installation

    Installation Antennas See Appendix B – Antenna Installation Mantracourt Electronics Limited T24 Technical Manual...
  • Page 34: T24-Saf [Strain Acquisition Fast]

    Read or set the digital output state. FLOAT ShuntCal Read or set the shuntcal state. UINT8 Status Live status where the bit values indicate status. The following table shows the decimal bit values and their meaning. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 35: Data Provider Format

    Note that the timestamp will restart from zero every 32.768 seconds. The Data Provider packet is typed as Binary. The 10 readings are next, each formatted as an INT32 (See Appendix A) and these are followed by the timestamp formatted as a UINT16. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 36: Measurement Resolution

    Measurement Resolution The noise free resolution is 15.5 bits ( 1:50,000) Power Supply See Appendix B – Acquisition Module Power Supply Installation Antennas See Appendix B – Antenna Installation Mantracourt Electronics Limited T24 Technical Manual...
  • Page 37: T24-Pa [Pulse Acquisition]

    UINT16 if no StayAwake command or trigger received. Setting to zero disables. DataTag Set or read the 2 byte Data Tag that is used when UINT16 transmitting the weight in a Data Provider Packet. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 38 No function other than to reset SleepDelay timer Command ResetCounter No function other than to reset the counter when in Command counter mode ResetTrigger Enter Data Tag to watch for that will reset the counter UINT16 when in count mode Mantracourt Electronics Limited T24 Technical Manual...
  • Page 39: Data Provider Format

    At every TXInterval a Data Provider packet is transmitted that holds 1 value in FLOAT format (See Appendix A). Power Supply See Appendix B – Acquisition Module Power Supply Battery Life See Appendix B – Acquisition Module Battery Life – Non Strain Gauge Input Installation Antennas See Appendix B – Antenna Installation Mantracourt Electronics Limited T24 Technical Manual...
  • Page 40: T24-Ra [Resistance (Potentiometer) Acquisition]

    Time required for the analogue readings to be stable. UINT16 Time before proper readings are taken. SleepDelay Time period before switching to low power sleep mode UINT16 if no StayAwake command or trigger received. Setting to zero disables. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 41 Make digital output mirror the LED state (V1.05 and later) Status Live status where the bit values indicate status. The following table shows the decimal bit values and their meaning. Bit Value Definition STATUS_SHUNT_CAL STATUS_INPUT_INTEGRITY Mantracourt Electronics Limited T24 Technical Manual...
  • Page 42: Data Provider Format

    Noise Free Resolution Ratio > 0 16 bits 1:65,000 > 9 17 bits 1:130,000 > 99 17.5 bits 1:190,000 > 999 17.75 bits 1:250,000 Power Supply See Appendix B – Acquisition Module Power Supply Mantracourt Electronics Limited T24 Technical Manual...
  • Page 43: Battery Life

    Battery Life See Appendix B – Acquisition Module Battery Life – Non Strain Gauge Input Installation Antennas See Appendix B – Antenna Installation Mantracourt Electronics Limited T24 Technical Manual...
  • Page 44: T24-Ta [Temperature Acquisition Pt100]

    DataTag Set or read the 2 byte Data Tag that is used when UINT16 transmitting the weight in a Data Provider Packet. Note that default value is set to last 2 bytes of ID. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 45: Data Provider Format

    NOTE: All changes require a SAVE command to enable them to survive through power cycle or RESET command. Data Provider Format At every TXInterval a Data Provider packet is transmitted that holds 1 value in FLOAT format (See Appendix A). Mantracourt Electronics Limited T24 Technical Manual...
  • Page 46: Measurement Resolution

    1:160,000 Power Supply See Appendix B – Acquisition Module Power Supply Battery Life See Appendix B – Acquisition Module Battery Life – Non Strain Gauge Input Installation Antennas See Appendix B – Antenna Installation Mantracourt Electronics Limited T24 Technical Manual...
  • Page 47: T24-Hs [Handheld Reader Simple]

    Set or read whether to perform wake and sleep on the UINT8 paired device when the handheld is powered up and down. ( range:0 to 1 default:1 ) Timeout Set or read the time in seconds that if exceeded UINT16 Mantracourt Electronics Limited T24 Technical Manual...
  • Page 48: Power Supply

    NOTE: All changes require a SAVE command to enable them to survive through power cycle or RESET command. Power Supply Recommend using alkaline AA cells as rechargeable are too low voltage and lithium may not be able to supply the current for the radio to start up. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 49: Installation

    Installation There are no specific installation instructions. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 50: T24-Ha [Handheld Reader Advanced]

    This transmits a Data Provider packet marked with a Data Tag held in F1DataTag and can also contain data as defined by F1Data. Power Toggles between on and off. Hold for 2 seconds to activate. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 51: Result Mode

    Toggles between on and off. Hold for 2 seconds to activate. Communications To configure the device you will use the Read and Write mechanisms described in the Data Packet Structures section to read and write parameters and execute commands. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 52: Parameter List

    Default = 0000.001 ZeroSupp Set or read whether to show the value on the display UINT8 with zero suppression. 0 = No zero suppression 1 = Zero suppression Mantracourt Electronics Limited T24 Technical Manual...
  • Page 53 Specifies the duration in milliseconds that messages UINT16 are displayed. i.e. the message that shows Input 1 or Input 2 as items are selected. ItemDuration Specifies the duration in seconds that individual item UINT8 Mantracourt Electronics Limited T24 Technical Manual...
  • Page 54 Wake key pressed in Bytes Items Mode. AllowNext Determines whether to allow the ability to view UINT8 individual items when in Result mode. Set to zero to disable or set to a number representing Mantracourt Electronics Limited T24 Technical Manual...
  • Page 55: Power Supply

    Recommend using alkaline AA cells as rechargeable are too low voltage and lithium may not be able to supply the current for the radio to start up. Installation There are no specific installation instructions. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 56: T24-Hr [Handheld Reader Roaming]

    Set to zero to reset. This property is used in ATE to test the keypad. Timeout Set or read the time in seconds that if exceeded UINT16 Mantracourt Electronics Limited T24 Technical Manual...
  • Page 57: Power Supply

    Recommend using alkaline AA cells as rechargeable are too low voltage and lithium may not be able to supply the current for the radio to start up. Installation There are no specific installation instructions. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 58: T24-So [Serial Output]

    Power Set or read the output power level. (0-100%) UINT8 Name Set or read a user defined name. (11 characters) STRING 11 byte Model Read the model number of the device. STRING 9 bytes Mantracourt Electronics Limited T24 Technical Manual...
  • Page 59 3 (Set in ValueDataTag3) exceeds this value then the <V3> token and any tokens using this value will result in '------' instead of a real value. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 60 <GRO> and <NET>. Leave as 0x00 to disable. ValueDataTag3 Read or set the 2 byte Data Tag of the Data Provider UINT16 Packet that the device uses as input 1. This will be stored Mantracourt Electronics Limited T24 Technical Manual...
  • Page 61 Read or set the data for line 18 of the serial output. You STRING 32 can include text or tokens. bytes Line19 Read or set the data for line 19 of the serial output. You STRING 32 Mantracourt Electronics Limited T24 Technical Manual...
  • Page 62 Read the set the text used to replace the <GN> token when STRING 10 in net mode. bytes PrintOnError Read the set whether to trigger a 'Print' output when an UINT8 error first occurs on any of the inputs. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 63: Tokens

    We want to put data from a T24-SA onto a large LED display. We will use the out of the box rate of 3 per second. The display only needs the ASCII data followed by a carriage return. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 64: Summed Led Display From Dual Source

    Input 1: xx.xxxx Kg Input 2: xx.xxxx Kg -------------------- Sum: xx.xxxx Kg For assistance call 0871 345672 Parameter settings: Line1=Mantracourt Electronics Ltd<0D><0A> Line2=Weigh Station #1<0D><0A> Line3=<0D><0A> Line4=Input 1:<V1> Kg<0D><0A> Line5=Input 2:<V2> Kg<0D><0A> Line6=---------------------<0D><0A> Line7=Sum: <GRO>Kg<0D><0A> Mantracourt Electronics Limited T24 Technical Manual...
  • Page 65: Customer Ticket From Handheld Device

    6 to 28 Volts dc. Installation The case can be mounted on a ceiling or wall. The module can be removed from the case and fitted to a DIN rail using an option kit. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 66: Connections

    Switch positions 5 to 7 control the baudrate for the serial interface. Whether the serial interface is RS485 or RS232 is selected by switch position 8. Baudrate / USB 9600 19200 38400 57600 115200 230400 460800 This switch position selects whether the serial interface is RS232 or RS485. 232/485 RS232 RS485 Mantracourt Electronics Limited T24 Technical Manual...
  • Page 67: T24-Ao1 [Analog Output]

    Restarts the device and utilises new channel and Command encryption keys if those have been changed and saved. Note after a Reset the device will be asleep. Save Save any changes made to parameters. Required before Command Mantracourt Electronics Limited T24 Technical Manual...
  • Page 68 Hold Last Output RemoteErrAction Select the action to trigger when the remote device UINT8 reports an error. Value Description None Minimum Full Scale Maximum Full Scale Minimum Output Maximum Output Half Full Scale Hold Last Output Mantracourt Electronics Limited T24 Technical Manual...
  • Page 69 Vout + Vout - Timeout I Sink + PAIR Error I Sink - Mode Batt Low I Source + Activity I Source - Timeout 9 to 36V dc Error Supply Batt Low Input Zero Mantracourt Electronics Limited T24 Technical Manual...
  • Page 70: Output Range Setting

    SW2 Switch Settings Range 0-10 V +/-10 V 0-5 V +/-5 V 0-20 mA Sink 0-20 mA Source 4-20 mA Sink 4-20 mA Source Where X = Don’t care Mantracourt Electronics Limited T24 Technical Manual...
  • Page 71: T24-Wss [Wind Speed Sensor]

    • The T24-WSS is powered either from internal batteries or an external supply. For applications which require high sampling rates for long periods Mantracourt’s PowerPack1 and SolarPanel1 (PP1 & SP1) offers an ideal solution. Communications To configure the device you will use the Read and Write mechanisms described in the Data Packet Structures section to read and write parameters and execute commands.
  • Page 72 Enter Data Tag to watch for that will reset SleepDelay UINT16 timer. DoSystemZeroTrigger Enter Data Tag to watch for that will reset SleepDelay UINT16 timer. NOTE: All changes require a SAVE command to enable them to survive through power cycle or RESET command. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 73: Data Provider Format

    Power Supply See Appendix B – Acquisition Module Power Supply Battery Life See Appendix B – Acquisition Module Battery Life – Non Strain Gauge Input. Note: Sensor can be assumed to draw zero current. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 74: Installation

    Installation Antennas See Appendix B – Antenna Installation Mantracourt Electronics Limited T24 Technical Manual...
  • Page 75: Appendix A

    SleepDelay time has elapsed if that is enabled. If the module was operating in low power mode you cannot communicate using the usual read/write commands as Mantracourt Electronics Limited T24 Technical Manual...
  • Page 76: Data Acquisition

    The following explains how to receive data provider packets, wake, issue StayAwake packets and sleep and for different drivers supplied by Mantracourt. Base stations using v2.00 or higher version radio modules offer additional support for the DPCI. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 77 Or with base station + v2.00 radio module RemoteWrite(BaseStation, Data Tag, 56, “”) Documentation for specific drivers supplied by Mantracourt will be included with the actual drivers which are available on the T24 Resource CD. This includes Windows DLL, Windows COM driver, Windows CE DLL and Windows CE Dot Net Assembly.
  • Page 78: Data Type Formats

    Data Type Formats The following data formats are used when communicating with the base station. These formats apply to the raw data in the packets and also to the data parts of the Mantracourt supplied T24drv.dll driver. Value Data Type...
  • Page 79: Rssi, Cv And Lqi

    CV = CV AND &H7F LQI is Link Quality Indication Mantracourt may also refer to Link Quality which is derived from the RSSI and CV values: LQI = (((94 + RSSI) + (CV - 55)) / 2) * 3.9 Which gives an operational range of approximately 0 to 255.
  • Page 80: Unslotted Csma/Ca

    0xFF and the data consists of a single Function byte which has fixed functionality depending on its value. The status byte is not used and may be left at zero. Function Byte Values Value Function None SLEEP PAUSE STAYAWAKE CONTINUE DOSYSTEMZERO REMOVESYSTEMZERO Mantracourt Electronics Limited T24 Technical Manual...
  • Page 81: Example

    If you wanted to keep all modules awake use 0xFFFF Data Tag instead of the module ID Packet Type To ID Command Data Type No each time the base station sees any Data Provider packet it will issue a STAYAWAKE command via DPCI. To pause the module you would use Mantracourt Electronics Limited T24 Technical Manual...
  • Page 82: Cancelling

    Data Provider packets occur. So if you inadvertently paused modules not part of your immediate system this could be problematic. When pausing multiple modules it is advised to pause them one at a time unless you know no other systems will be operating on your radio channel. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 83: Appendix B

    Signal power at the input of the receiver = -64.46dBm Note that although the manufacturer’s data sheet for the chip antenna gives gain as 3dBi Peak, this figure is rarely achieved in practice; between 1 and 1.5dBi is more usual. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 84: Example 3

    T24-HS. In the case of the T24-BS however, peak gain of the PCB antenna is 6dB and the enclosure loss is between 3 and 5dB depending on composition of the ABS. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 85: Example 4

    So the estimated power at the receiver input is -77.22dBm Refer to Table 1 below that shows the relationship between receiver input power and RSSI, an input level of - 77.22dBm will result in an RSSI between -80 and -85. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 86: Antenna Basics

    10 and the corresponding input levels recorded at each step. Figures in italics were not measured but extrapolated from the measured values. Input signal power Indicated RSSI (dBm) Value -28.5 -36.5 -44.5 Mantracourt Electronics Limited T24 Technical Manual...
  • Page 87: Path Loss At 2.4Ghz

    78.20 80.69 These figures are for free-space path loss only, when estimating signal power at the receiver input, take the sum of all the gains and then subtract the sum of all the losses. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 88: Power Density

    4mW assuming a 6dB antenna. Antenna Installation Internal Chip Antenna There must be no metal objects within 7mm of the antennas long edge and 20mm from the short edges. See diagram below Mantracourt Electronics Limited T24 Technical Manual...
  • Page 89 7 mm Mantracourt Electronics Limited T24 Technical Manual...
  • Page 90: External Antennas

    These batteries self discharge at a faster rate than alkalines. If charging these cells in circuit precautions must be taken to ensure that the maximum voltage on the T24-SA is not exceeded. Example: GP 270AAHC (AA) Recommend T24-PSSA module to maximise usable capacity. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 91: In-Line Battery Modules

    Example of 2 X AA GP 15A with a usable capacity of 1.9Ah. The loadcell is 1K and the transmission rate is 3Hz with a 5 millisecond sample time. Years = (10 / 0.33) Years = 0.063 = 23.1 days Mantracourt Electronics Limited T24 Technical Manual...
  • Page 92: Accurate Guide

    BattAH = Usable battery capacity in Amp Hours (Ah) WakeInt = WakeChkInt parameter FixedMeasurementCurrent = 45 Internally the device will adjust SampleTime if it is too long for the TXInterval so we need to take this into account for our calculations: Mantracourt Electronics Limited T24 Technical Manual...
  • Page 93: Acquisition Module Battery Life – Non Strain Gauge Input

    If SampleTime + 0.025 > TXInterval then we need to make SampleTime = TXInterval - 0.025 Also note that we cannot use a TXInterval of less than 0.041 if we are in low power mode as this will cause unpredictable results. Mantracourt Electronics Limited T24 Technical Manual...
  • Page 94 TotalCurrent = AwakeCurrent + SleepCurrent Calculate battery life in hours BattHours = (BattAH / TotalCurrent) * 1000 Allow a safety margin BattHours = BattHours * 0.9 The calculated battery life in hours is BattHours Mantracourt Electronics Limited T24 Technical Manual...
  • Page 95: Appendix C

    Appendix C Customising T24 Toolkit Some customers re-badge the Mantracourt instrumentation and this section explains how to ship a custom version of the T24 Toolkit with custom model names, images and descriptions. To construct a customised setup the customer will need to create a sub-folder named Custom in the folder where the setup.exe file is located.
  • Page 96: Appendix D

    (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: If the device is changed or modified without permission from Mantracourt Electronics Ltd, the user may void his or her authority to operate the equipment.
  • Page 97: Oem / Reseller Marking And Documentation Requirements

    2. The T24-Sae module may be used only with Approved Antennas that have been tested by Mantracourt. Labelling requirements for Industry Canada are similar to those of the FCC. A clearly visible label on the outside of the final product enclosure must display the following text: Contains Model RAD24 Radio (2.4 GHz), IC:7224A-RAD24...
  • Page 98: Worldwide Regional Approvals

    Mantracourt, or refer to the following web site: www.ero.dk ISO 9001 REGISTERED FIRM In the interests of continued product development, Mantracourt Electronics Limited reserves the right to alter product specifications without prior notice. DESIGNED & MANUFACTURED IN THE UK Code No. 517-908 Issue 2.9...

Table of Contents