Download Print this page
Hitachi RA-08LEDF Operation And Installation Manual
Hitachi RA-08LEDF Operation And Installation Manual

Hitachi RA-08LEDF Operation And Installation Manual

Window type room air conditioner

Advertisement

Quick Links

WINDOW TYPE ROOM AIR CONDITIONER
OPERATION AND INSTALLATION MANUAL

SAFETY PRECAUTION

Read the safety precautions carefully before operating the unit.
The contents of this section are vital to ensure safety. Please pay special attention to the following sign.
WARNING ........ Incorrect methods of installation may cause death or serious injury.
CAUTION ......... Improper installation may result in serious consequence.
The sign in the À gure indicates prohibition.
Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating the unit
as described in the user's manual.
PRECAUTIONS DURING INSTALLATION
Please ask sales agent or qualiÀ ed technician for the installation of the unit. Water leakage,
short circuit or À re may occur if install the unit improperly.
WARNING
Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line
of telephone. Improper installation of earth line may cause electric shock.
A circuit breaker should be installed depending on the mounting site of the unit. Without
CAUTION
a circuit breaker, the danger of electric shock exists.
Do not install near location where there is Á ammable gas. The unit may catch À re if
Á ammable gas leaks around it.
If drain pan is used, please ensure that when installing the drain hose, water is able to
Á ow freely without any obstruction.
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
If abnormal situation arises (like burning smell), please stop the unit and turn off the
circuit breaker. Fault, short circuit or À re may occur if the unit is continue to operate under
abnormal situation.
Please contact your agent for maintenance. Improper maintenance may cause electric
WARNING
shock and À re.
Please contact your agent if need to remove and reinstall the unit. Electric shock or À re
may occur if you remove and reinstall the unit improperly.
PARTS IDENTIFICATION AND OPERATIONS
Model
Width
Height
RA-08LEDF
1
1
18
¼
", 470mm
13
¼
", 345mm
2
2
RA-10LEDF
RA-13LEDF
22
3
¼
", 560mm
14
3
¼
", 375mm
64
4
CONTROL PANEL
TEMPORARY SWITCH
Use this switch to start operation and stop
when the remote controller does not work.
Normally do not use this switch
TEMPORARY SWITCH
Use the temporary switch for start or stop operation when operation cannot be done with the remote controller.
By pressing the temporary switch, [use non-conductor stick (for example: toothpick),] the operation will follow previous
operation mode.
When the operation is done using the temporary switch, after the power source is turned off and is turned on again, the
operation is done in automatic mode.
<
>
IA1049: A
MODEL
RA-08LEDF
RA-10LEDF
RA-13LEDF
1
Cabinet
2
Suction Grille
3
Front Cover
4
Horizontal DeÁ ectors
5
Vertical DeÁ ector
6
Air Exhaust Lever
7
Switch Panel Cover
Depth
3
25
¼
", 640mm
16
27
29
¼
", 709mm
32
INDICATION LAMP
OPERATION LAMP
DEHUMIDIFY LAMP
POWER SWITCH
AIR DEFLECTORS
VERTICAL DEFLECTORS
Vertical deÁ ectors at both sides of outlets can be set to
either auto-swing or static position to direct discharge air
rightward, leftward or forward direction.
CAUTIONS
To avoid dew forming on the deÁ ectors which eventually may drip to the Á oor, please do not adjust horizontal deÁ ectors
extremely downward position or vertical deÁ ectors extremely leftward or rightward position during cool operation for a long
time.
Also, do not adjust the vertical deÁ ectors position by hand or any other object.
AIR EXHAUST LEVER
Set the air exhaust lever to the down ( OPEN) position for air ventilation in
the room. The air exhaust lever should normally be kept in up ( CLOSE)
position during cooling operation and in the case of typhoon.
AIR PURIFYING FILTER
Always stop the operation before installing the air purifying À lter.
1. Pull and remove the suction grille
Air purifying À lter is washable and can be use for 1 year time. Type number for this air purifying À lter is <SPX-CFH8W>.
Please use this number for ordering when you want to renew it.
NOTES ON OPERATION
TEMPERATURE AND HUMIDITY
Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21°C (70°F). Recommended
operation humidity should be below 80%. Continuous operation at over 80% humidity (indoor) will cause some dews form
on the outlet grille and deÁ ectors of the unit.
NOISE
In a quiet environment during the starting or stopping the operation, phenomena like Á owing sound of refrigerant in the
refrigerating cycle and rubbing noise from the fan casing may occasionally occur, but this is normal for the operation.
Water will be condensed on the evaporator coil and collected in the bottom tray, it is picked up by the condenser fan and
blown onto the condenser coil, this creates a "splashing" sound which is normal.
ODOR
The odor will possibly be emitted from the room air conditioner especially at the starting of operation and in a high
humidity condition. This is not abnormal phenomena because of the various kind of odors emitted by smoke, food stuffs,
cosmetics and others which may stick to the room air conditioner. So, the pre-À lter and the evaporator regularly must be
cleaned to reduce the odor.
THE IDEAL WAYS OF OPERATION
Suitable Ro
Temperature
Warning
Freezing temperature
is bad for health and a
waste of electric power.
Do Not Forget To Clean The Pre-Filter
Dusty pre-À lter will reduce the air
volume and the cooling efÀ ciency.
To prevent from wasting electric
energy, please clean the pre-À lter
every 20 days.
FOR USER'S INFORMATION
The Air Conditioner And The Heat Source In The Room
TIMER LAMP
Caution
If the amount of heat in the room is above the cooling capability of the air conditioner (for
example: more people entering the room, using heating equipments and etc.), the preset
room temperature cannot be achieved.
Warning
To protect the unit during lightning, please stop operating the unit and remove the plug
from the socket.
HORIZONTAL DEFLECTORS
Horizontal deÁ ectors at both sides of the outlets can
be set to direct discharge air upward, downward or
forward direction.
2. Remove the pre-À lter
3. Install the air purifying À lter in
the frame
4. Install back the pre-À lter and
close the suction grille
Install curtain or blinds
Caution
It is possible
Do not close the room for a long period of
to reduce heat
time. Occasionally
entering the room
open the door and
through windows.
windows to allow the
entrance of fresh air.
Please Adjust Suitable Temperature
For Baby And Children
Please pay attention to the
room temperature and air Á ow
direction when operating the
unit for baby, children and old
people who have difÀ culty in
movement.
When Lightning Occurs
Ventilation

Advertisement

loading

Summary of Contents for Hitachi RA-08LEDF

  • Page 1: Safety Precaution

    AIR DEFLECTORS MODEL RA-08LEDF VERTICAL DEFLECTORS HORIZONTAL DEFLECTORS RA-10LEDF RA-13LEDF Vertical deÁ ectors at both sides of outlets can be set to Horizontal deÁ ectors at both sides of the outlets can either auto-swing or static position to direct discharge air...
  • Page 2: Installation Instructions

    Use a fuse as below: PRE-FILTER Voltage rating 50Hz 220V RA-08LEDF If the pre-À lter is clogged with dust, the air Á ow volume will be decreased and resulting in poor cooling performance, and CAUTION RA-10LEDF 15A time delay fuse Operatable increased operating noise.
  • Page 3: Names And Functions Of Remote Controller

    ON TIMER Cancel ON TIMER MODEL: RA-08LEDF, RA-10LEDF and RA-13LEDF Operation will start for setting temperature at setting time (The starting time may Transmission sign different depend on the room temperature and set temperature).
  • Page 4: Cooling Operation

    COOLING OPERATION CIRCULATION OPERATION Use the device for cooling when the outdoor temperature is 21 ~ 43°C. Press the (CIRCULATION) button so that the display indicates pointing to button. If indoor humidity is very high (over 80%), some dew may form on the air outlet grille and deÅ ectors of the unit. Circulating operation starts with a beep.

This manual is also suitable for:

Ra-10ledfRa-13ledfRa-08lfRa-10lfRa-13lf