Honeywell Krom Schroeder TZI Operating Instructions Manual

Ignition transformers

Advertisement

Quick Links

Ignition transformers tZI, tGI
Contents
1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2 Checking the usage . . . . . . . . . . . . . . . . . . . . . 2
3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4 Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
5 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . 5
8 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 6
9 Logistics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
10 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . 8
11 Certification . . . . . . . . . . . . . . . . . . . . . . . . . . 8
12 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
oPeRAtInG InstRUCtIons
Cert. Version 12.22 · Edition 12.23 · EN · 03251630

1 sAFetY

1.1 Please read and keep in a safe place
Please read through these instructions
carefully before installing or operating. Following the
installation, pass the instructions on to the operator.
This unit must be installed and commissioned in
accordance with the regulations and standards in
force. These instructions can also be found at www.
docuthek.com.
1.2 explanation of symbols
1  , 2  , 3  , a  , b  , c  = Action
➔ = Instruction
1.3 Liability
We will not be held liable for damage resulting from
non-observance of the instructions and non-com-
pliant use.
1.4 safety instructions
Information that is relevant for safety is indicated in
the instructions as follows:
DAnGeR
Indicates potentially fatal situations.
WARnInG
Indicates possible danger to life and limb.
CAUtIon
Indicates possible material damage.
All interventions may only be carried out by qualified
gas technicians. Electrical interventions may only be
carried out by qualified electricians.
1.5 Conversion, spare parts
All technical changes are prohibited. Only use OEM
spare parts.

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell Krom Schroeder TZI

  • Page 1: Table Of Contents

    Ignition transformers tZI, tGI oPeRAtInG InstRUCtIons Cert. Version 12.22 · Edition 12.23 · EN · 03251630 1 sAFetY 1.1 Please read and keep in a safe place Please read through these instructions carefully before installing or operating. Following the installation, pass the instructions on to the operator. This unit must be installed and commissioned in accordance with the regulations and standards in force.
  • Page 2: Checking The Usage

    2.2 Part designations 2 CHeCKInG tHe UsAGe 2.2.1 tZI tZI, tGI For the high-voltage ignition of gas burners and gas-ignited or directly ignited oil burners with a one-pole output to the protective earth. The ignition transformers can also be used on burners with sin- gle-electrode operation.
  • Page 3: Installation

    3 InstALLAtIon 4 WIRInG ➔ Cable for burner ground/PE wire: 4 mm CAUtIon ➔ tGI: mains power cable: max. 1.5 mm Incorrect installation! ➔ For the ionization and ignition cables, use un- Please observe the following to ensure that the screened high-voltage cable: unit is not damaged during installation and oper- FZLSi 1/7 -50 to +180°C (-58 to +350°F), Order ation:...
  • Page 4 4.1 Connection diagram Legend High-voltage connection PE wire connection Burner ground connection Flame control Burner control unit tZI/tGI..e tZI/tGI..t L = black core L = black core n = blue core n = white core Brown core Red core Pe = green/ Pe = green core yellow core Double-electrode operation...
  • Page 5: Commissioning

    5 CoMMIssIonInG 7 AssIstAnCe In tHe eVent oF MALFUnCtIon WARnInG Danger of death! WARnInG High voltage is supplied to the high-voltage con- Electric shocks can be fatal! nection on the TZI, TGI during the ignition process. – Before working on possible live components, ➔...
  • Page 6: Technical Data

    Duty cycle [%]: 8 teCHnICAL DAtA Mains voltage: TZI..Q, TGI..Q: 120 V AC, 50/60 Hz, TZI..W, TGI..W: 230 V AC, 50/60 Hz. Output voltage: TZI 5, TGI 5: 5 kV, TZI 8, TGI 8: 8 kV. Electrode distance: 2 ± 0.5 mm. Length of ignition cable: < 1 m (3.28 ft), max. 5 m (16.4 ft).
  • Page 7: Logistics

    type Input output Duty cycle TGI 5-15/100QE (0.6) (11) TGI 5-15/100QT (0.6) (11) TGI 5-15/100WE (0.3) (10) TGI 8-20/19QE (1.4) (16) TGI 8-20/19QT (1.4) (16) TGI 8-20/19WE (0.7) (16) TGI 8-12/100QE (0.9) TGI 8-12/100QT (0.9) TGI 8-12/100WE (0.4) TGI 8-20/33QE (1.3) (16) TGI 8-20/33QT (1.3) (16) TGI 8-20/33WE (0.7) (16) Values in brackets apply to 60 Hz. Within 3 minutes at -20 to +35°C.
  • Page 8: Accessories

    Scan of the Declaration of conformity (D, GB) – see www.docuthek.com FoR MoRe InFoRMAtIon The Honeywell Thermal Solutions family of products includes Honeywell Combustion Safety, Eclipse, Exothermics, Hauck, Kromschröder and Maxon. To learn more about our products, visit ThermalSolutions.honeywell.com or contact your Honeywell Sales Engineer.

This manual is also suitable for:

Krom schroeder tgi

Table of Contents