Download Print this page

Sharp NB-JD545 Installation Manual

Crystalline photovoltaic module

Advertisement

Quick Links

PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR USING THE PV MODULES.
PLEASE PASS ALONG THE ATTACHED USER MANUAL TO YOUR CUSTOMER.
# IMPORTANT SAFETY INSTRUCTIONS
# GENERAL INSTRUCTIONS
# INSTALLATION INSTRUCTIONS -PHOTOVOLTAIC MODULES-
# ELECTRICAL OUTPUT AND THERMAL CHARACTERISTICS
# ANNEX (NORMATIVE)
IMPORTANT SAFETY INSTRUCTIONS
This manual contains important safety instructions for the PV module
that must be followed during the maintenance of PV modules.
To reduce the risk of electric shock, do not perform any servicing
unless you are qualified to do so.
1.
The installation must be performed by a certified installer
/servicer to ensure system integrity and safety.
2.
The
installation
is
understanding of this INSTALLATION MANUAL. If you don't
have your personal copy, please contact your installer or local
SHARP
office
listed
https://www.sharp.eu/
3.
Do not pull the PV cables.
4.
Do not touch any surface of PV module.
5.
Do not place/drop objects onto the PV modules.
6.
Do not disassemble or attempt to repair the PV module by
yourself.
7.
Do not drop the PV module.
8.
Do not damage, pull, bend, or place heavy material on cables.
9.
Upon completion of any service or repairs, ask the
installer/servicer to perform routine checks to determine that
the PV modules are in safe and proper operating condition.
1. INTRODUCTION
This INSTALLATION MANUAL contains essential information for the electrical and mechanical installation that you must know
before installing SHARP PV modules. This also contains safety information you need to be familiar with. All the information
described in this manual are the intellectual property of SHARP and based on the technologies and experiences that have been
acquired and accumulated in the long history of SHARP. This document does not constitute a guaranty, expressed or implied.
SHARP does not assume responsibility and expressly disclaims liability for loss, damage, or expense arising out of or in any way
connected with installation, operation, use or maintenance of the PV modules. No responsibility is assumed by SHARP for any
infringement of patents or other rights of third parties that may result from use of PV module. SHARP reserves the right to make
changes to the product, specifications or INSTALLATION MANUAL without prior notice.
2. COMPONENTS
Connector
Junction Box
Frame
INSTALLATION MANUAL
- Crystalline Photovoltaic Module -
NB-JD545, NB-JD550
only
allowed
after
referring
in
SHARP
Solar
web
GENERAL INSTRUCTIONS
Solar Photovoltaic Cell
Electriclal Cable
Glass
MODEL
10. When
replacement
installer/servicer uses parts specified by the manufacturer with
same characteristics as the original parts. Unauthorized
substitutions may result in fire, electric shock, or other hazard.
11. Consult your local building and safety department for required
permits and applicable regulations.
12. As a result of sliding snow, the mechanical load increases when
and
the number of PV module rows in the matrix of a PV installation
increases. When mounting the PV module in the portrait
orientation for more than 3 rows, the accumulated snow load
site
:
may cause the lower edge of the PV module frame to deform.
Take necessary measures (e.g. snow stopper) to avoid
possible damage.
13. Periodically remove any overhanging snow and/or ice from the
PV module framework as it may cause deformation of the PV
module frame.
CAUTION: HIGH VOLTAGE
To reduce the risk of electric shock, do not touch.
3. GENERAL INFORMATION
(INCLUDING WARNING AND SAFETY)
The installation of PV modules requires a great degree of skill
and should only be performed by a qualified licensed
professional, including licensed contractors and licensed
electricians. Please be aware that there is a serious risk of
various types of injury occurring during the installation including
the risk of electric shock. All SHARP PV modules are equipped
with permanently attached junction boxes that will accept
variety of wiring applications or with a special cable assembly
for ease of installation, and they do not require special
assembly.
GENERAL WARNING
1.
PV modules are heavy. Handle with care.
2.
Before you attempt to install, wire, operate and maintain
the PV module, please make sure that you completely
understand
INSTALLATION MANUAL.
3.
Contact with electrically active parts of a PV module such
as terminals can result in burns, sparks and lethal shock
1
SIM03E-001B+C
p.1
p.1 ~ p.4
p.4
p.5
p.6
parts
are
required, be
the
information
described
sure
the
in
this

Advertisement

loading

Summary of Contents for Sharp NB-JD545

  • Page 1 PV modules. No responsibility is assumed by SHARP for any infringement of patents or other rights of third parties that may result from use of PV module. SHARP reserves the right to make changes to the product, specifications or INSTALLATION MANUAL without prior notice.
  • Page 2: General Safety

    10. Do not touch the PV module with bare hands. The frame In the case that the PV modules are non-integral type, the of PV module has sharp edges and may cause injury. PV module is to be mounted over a fire resistant roof.
  • Page 3: Site Selection

    NOT CERTIFIED by a third party organization. 1 & 2) when connecting the PV modules to a battery or to other The approved way to mount SHARP PV modules to a support PV modules. If not connected correctly, the bypass diodes could structure is described in this INSTALLATION MANUAL.
  • Page 4: Maintenance

    SIM03E-001B+C Although SHARP does not specify or warrant frame clamps or When mounting the PV module on structure, ensure that no clips, using frame clamps (not provided) or clips (not provided) corner has a displacement of more than 2mm per every 1,000 is possible when they are designed for PV modules and with mm of the diagonal.
  • Page 5 Voltage Current of max. Power of max. Power series against name system voltage Protection elecric al (Pmax) (Voc) (Isc) (Vmpp) (Impp) configuration(*) shock NB-JD545 545W +5%/-0% 50,40V 13,77A 42,25V 12,90A 1.500V Ⅱ 572W 50,40V 14,46A 42,25V 13,55A Power 627W 50,40V...
  • Page 6 SIM03E-001B+C Annex (normative) 【Test load】 【Design load】 Table.A1(-1) Test load using clamps on long frames (see Fig. A1) Table.A1 Design load using clamps on long frames (see Fig. A1) test load design load clamp center position clamp center position downward force upward force downward force upward force...

This manual is also suitable for:

Nb-jd550