Sealey AB708.V2 Manual

Sealey AB708.V2 Manual

Space warmer paraffin / kerosene / diesel heaters

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Warning!
instructions
automatic
start-up
This product is not suitable for primary heating purposes
1. SAfETy
1.1.
ElECTRiCAl SAfETy
WARninG! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets
and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of
appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. You
must also read and understand the following instructions concerning electrical safety.
ensure that cables are always protected against short circuit and overload.
9
Regularly inspect power supply cables and plugs for wear or damage and check all connections
9
to ensure that none are loose.
ensure that the voltage marked on the appliance matches the power supply to be
9
used and that the plug is fitted with the correct fuse - see fuse rating at right.
do noT use worn or damaged cables, plugs or connectors. Have any faulty item repaired or
8
replaced immediately by a competent electrician.
It is recommended that this heater is wired directly to a fused isolator switch. If, however, a plug
9
is fitted, the following applies:
Fit a new plug according to the following instructions (UK only).
9
a) Connect the GReen/YelloW earth wire to the earth terminal 'e'.
b) Connect the BRoWn live wire to the live terminal 'l'.
c) Connect the BlUe neutral wire to the neutral terminal 'n'.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected,
that the cable restraint is tight.
GEnERAl SAfETy
1.2.
dAnGER! Risk of carbon monoxide poisoning. Failure to provide proper ventilation could result in serious illness or death.
Check that the heater is in sound condition and good working order. Take immediate action to repair or replace damaged parts.
9
Use recommended parts only. Unapproved parts may be dangerous and will invalidate the warranty.
9
only use clean paraffin, kerosene or diesel (noT Bio-diESEl) to fuel your heater, in accordance with instructions contained in this
9
manual
WARninG! only use heater in well ventilated areas. ensure continuous ventilation from outside of the building is provided to the
heater operating area. Allow at least 3ft² opening/100000Btu/hr output.
Keep the front of the heater a minimum of 2.4 metres and the rear and sides1.2 metres from any combustible materials (i.e. wooden
9
items, cloth, plastics, paper,tarpaulins or similar enclosure materials).
only operate on a level and stable surface.
9
WARninG! do noT use the heater near flammable material, liquids, solids, gases or compressed gas cylinders.
do noT use the heater in closed rooms, living areas, basements or below ground level.
8
do noT allow untrained persons to operate the heater and do noT operate the heater without the cover.
8
do noT move or handle the heater when hot.
8
do noT leave the heater unattended when in use. Switch the heater off and unplug from the mains before leaving work area.
8
do noT fill the fuel tank whilst the heater is running or still hot.
8
do noT overfill the fuel container. Wipe up any spilt fuel immediately.
8
do noT obstruct the air inlet (rear) and air outlet (front) of the heater. do noT use duct work in front or at the rear of the heater.
8
do noT look into the exhaust end of the heater.
8
do noT allow children or animals near the heater when in use, or while hot.
8
WARninG! RiSk of ElECTRiC SHoCk. do noT expose the heater to water spray, rain, dripping water or wind.
do noT operate the heater when you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
do noT touch the heater outlet or dome when first switched off as these are very hot and will take time to cool.
8
ensure that the heater is correctly turned off when not in use and store in a safe, dry area, out of reach of children.
9
do noT unplug the heater to switch it off. Use the on/oFF switch.
8
WARninG! Improper maintenance can lead to poor combustion and soot production
noTE:
This appliance is not intended for persons (including children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
© Jack Sealey limited
SPACE WARMER PARAffin / kERoSEnE /
diESEl HEATERS
Model no:
Warning!
Warning!
Hot surfaces
Original Language Version
AB708.V2, AB7081.V2
AB708.V2, AB7081.V2 Issue:8 (eRP) 12/07/19
Recommended fuse rating
13 Amp

Advertisement

Table of Contents
loading

Summary of Contents for Sealey AB708.V2

  • Page 1 AB708.V2, AB7081.V2 Model no: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Specification

    Place handle on fuel tank flange and line up with the wheel support frame fixing holes. fig.4 Insert bolts provided through the fuel tank flange and both frames and secure finger tight only with nuts and washers provided. © Jack Sealey limited Original Language Version AB708.V2, AB7081.V2 Issue:8 (eRP) 12/07/19...
  • Page 3: Storage Of Fuel

    The electrical components of these heaters are protected by a fuse mounted on the PC board. If the heater will not fire, check this fuse first and replace if necessary. Also check that the proper voltage is being supplied to the heater. © Jack Sealey limited Original Language Version AB708.V2, AB7081.V2 Issue:8 (eRP) 12/07/19...
  • Page 4: To Stop The Heater

    WARninG! never attempt to service the heater whilst it is still hot, wait until it has cooled enough to touch. unplug the heater ‰ from the mains supply before servicing. Use only genuine Sealey replacement parts. Use of alternative/third party components will cause unsafe operation and will invalidate your warranty. 8.2.
  • Page 5: Pump Pressure

    Although our heaters operate with diesel fuel, when the temperature is below 0°C diesel additives are required to maintain the diesel’s viscosity. Typically diesel can cloud in freezing conditions and will start to gel. You will need additives for your fuel in these conditions. Kerosene/Paraffin does not start to gel until the ambient temperature is around -40°C. AB708.V2, AB7081.V2 Issue:8 (eRP) 12/07/19 © Jack Sealey limited Original Language Version...
  • Page 6: Troubleshooting

    Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call our technical team on technical@sealey.co.uk or 01284 757505. important: no liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. iP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk...
  • Page 7 The seasonal space heating Energy efficiency in active mode ƞ s,on The seasonal space heating energy efficiency ƞ ƞ 90.1 90.1 Energy efficiency classes Contact details: Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk, IP32 7AR. www.sealey.co.uk ERP Table 1...
  • Page 8 The seasonal space heating Energy efficiency in active mode ƞ s,on The seasonal space heating energy efficiency ƞ ƞ 90.1 90.1 Energy efficiency classes Contact details: Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk, IP32 7AR. www.sealey.co.uk ERP Table 1...

This manual is also suitable for:

Ab7081.v2Ab7081

Table of Contents