Quincy lab Digital Series Operating Manual

Quincy lab Digital Series Operating Manual

Advertisement

Quick Links

uincy
ab
SPECIFICATIONS
Interior Dimensions
Exterior Dimensions
Weight (lbs)
Cubic Foot Capacity
Standard Electrical
Temperature Range
Common Unit Specifications
Operating Environment: Indoor use, altitude to 6,500 ft. (2,000m) Installation Category II,
Storage Temperature:
Approvals:
Compliance:
Common Unit Construction
Exterior: Powder-Coated Steel
Insulation: Fiberglass
Thermo-control: PID Microprocessor
Issue Rev 06.22
Copyright Quincy Lab Inc. 2022
Model 12-140E
MODEL
10-140E
12x10x10
INCHES W x H x D
31x25x25
(CM) W x H x D
13x15x11
INCHES W x H x D
33x38x28
(CM) W x H x D
19 lbs
115 / 120*
VOLTS / WATTS
Pollution Degree 2, ambient temperature 10
80% RH maximum.
o
-10
C/14
Underwriter's Laboratory Listed, Laboratory Equipment, C/UL
United States/Canadian. E212550 (115VAC models only)
UL Standard 61010-1, IEC 61010-1, 2nd Edition.
Quincy Lab Inc. 109 Shore Dr.
Digital Series Incubator
MODEL
12-140E
18x16x12
46x41x30
19x21x13
48x53x33
33 lbs
115 / 235*
o
o
o
F to 70
C/158
F, 70% RH maximum.
Interior: Aluminum
Door: 140E: Acrylic, 180E: Steel Insulated
Heater: Resistive-Tubular Incoloy
Burr Ridge, Illinois 60527
Operating Manual
For models 140E & 180E
Model 10-180E
MODEL
MODEL
10-180E
12-180E
12x10x10
18x16x12
31x25x25
46x41x30
13x15x11
19x21x11
33x38x28
48x53x33
19 lbs
33 lbs
115 / 270*
115 / 385*
o
o
o
C/50
F to 35
C/95
1800-482-4328
o
F,
PAGE 1

Advertisement

loading

Summary of Contents for Quincy lab Digital Series

  • Page 1 Exterior: Powder-Coated Steel Interior: Aluminum Insulation: Fiberglass Door: 140E: Acrylic, 180E: Steel Insulated Thermo-control: PID Microprocessor Heater: Resistive-Tubular Incoloy Issue Rev 06.22 Quincy Lab Inc. 109 Shore Dr. Burr Ridge, Illinois 60527 1800-482-4328 Copyright Quincy Lab Inc. 2022 PAGE 1...
  • Page 2: General Operation

    Safety Precautions Safety Precautions Read Operating Instructions Thoroughly Prior to Operation Read Opera�ng Instruc�ons thoroughly prior to opera�on and observe the following safety precau�ons: • Use only a grounded outlet that is rated for your model's electrical requirement. • Do not modify the unit or factory control se�ngs to operate the unit above the stated maximum opera�ng temperature. •...
  • Page 3 Menu Functions Guide To navigate the controller's menu, please refer to the easy-to-use Menu Guide below: Menu setting changes can be done quickly with our 4-button digital microprocessor. Your incubator's controller allows you to perform the following: Auto-tune your Incubator for maximum efficiency Set the operating set-point temperature Lock the set-temperature Select between degrees Fahrenheit or Centigrade...
  • Page 4 AUTO-TUNING THE UNIT Your unit’s controller has been tuned from our factory to Once the desired set-point temperature has been set, achieve set-point temperatures at a faster rate. However, you will need to input the factory set passcode to access you can auto-tune your unit’s controller to work best with the tuning parameter.
  • Page 5 Chamber Loading Understanding the unit's light pressure thermal convec�on and "load-effect" are necessary to op�mize unit performance. Ar�cle or media processing �mes and/or uniformity are largely dependent on load density and posi�oning. Important guidelines to chamber loading and processing: Load the incubator so that air circula�on within the chamber is not impaired. Leave a space between ar�cles on the shelf.
  • Page 6: Maintenance

    For a complete list of replacement components, part and additional equipment, visit us on the web at www.quincylab.com Technical Support If you have any ques�ons or need technical assistance, contact Quincy Lab technical support for further assistance, or visit us on the web at www.quincylab.com Email: information@quincylab.com...

This manual is also suitable for:

140e series180e series10-140e12-140e10-180e12-180e