JP346WM/CM/BM
GE
30" Built-In CleanDesign Electric Cooktop
®
Dimensions and Installation Information (in inches)
Note: If installing with a GE Profile
KW Rating
Downdraft System, consult both cooktop and
240V
7.6
downdraft installation instructions packed with
product before installing. Cooktop gas/electric supply
208V
5.7
may need to be re-routed to install downdraft.
Breaker Size
Note: Consult cabinet and countertop
manufacturer's specs for flush mount installation
240V
40 Amps
prior to install.
208V
30 Amps
Installation Information: Requires a 5" free
area between the bottom of the cooktop to any
combustible material, i.e., shelving. Free area not required when installing
wall oven underneath cooktop. Refer to installation instructions. Requires
a 15" minimum from cooktop to adjacent overhead cabinets. Units are
furnished with a 48" flexible armored cable.
Before installing consult installation instructions, packed with product, for
current dimensional data. 36" Ribbon cooktops are approved for use over GE
30" Single Wall Ovens only. 30" Ribbon cooktops are approved for use over
select GE 27" and GE 30" Single Wall Ovens. Refer to cooktop and wall oven
installation instructions packed with product for current dimensional data.
Filler Trim Kit
When replacing an old GE 30" cooktop (with larger opening) use the following
one-piece trim kit to fill in the over-size hole. Available at additional cost.
JXTR32B (Black glass with black, white or bisque pattern)
For answers to your Monogram,
GE Profile
®
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
800.626.2000.
Telescopic
™
or
™
service,
21-3/8
29-3/4
Cooktop
19-5/8
28-1/2
2-1/2**
Required
* Depth of unit at conduit connection location (rear) is
6-1/2" on models PP980/950 and 4-5/8" on models
PP975/972/962/945/942/932/912, JP655/356/346.
**Raised bull nose countertops may require up to
3/8" additional clearance to prevent interference
with curved front.
30_color_cktp_install.eps
13" MAX.
depth
3-1/4*
30" MIN. to
unprotected
cabinet
15" MIN.
to cabinet
1-3/4" to
rear wall
1-1/2" MIN.
clearance to
side wall
from cut-out
Electrical junction box 16" MIN.
below countertop
Specification Created 10/06
1-1/2" MIN.
clearance to
side wall
from cut-out
Cut should
not interfere
with cabinet
structure
at front
Listed by
Underwriters
Laboratories
321358