DPG1000L
DPG1001L
DPG1000L
DPG1101L
Ranges and Resolution
Resolution is fixed as indicated below
3-1/2 digit model ranges are limited by number of display digits: 2,
20, 200, and 2000 ranges display 1.999, 19.99, 199.9, and 1999.
psig
Gauge reference pressure
psig vacuum Vacuum gauge, minus sign not used
psia
Absolute reference (open port reads atmospheric
pressure, reads zero at full vacuum)
Available Ranges
15.00 psig vacuum
30.0 inHg vacuum
±15.0 psig
3.00 psig
5.00 psig
15.00 psia
15.00 psig
30.0 psia
30.0 psig
60.0 psig
100.0 psia
100.0 psig
199.9 psig
300 psig
500 psig
1000 psig (1KG)
1999 psig (2KG)
3000 psi (3KG) *
5000 psi (5KG) *
Bold Standard ranges. Contact Omega Engineering or other
engineering units such as kPa, atm, bar, mbar, inHg,
mmHg, inH 2 O, ftH 2 O, torr, kg/cm
DPG1001L , DPG1101L (high accuracy) not available in
3 psi, 5 psi, vacuum, or bipolar ranges.
DPG1001L , DPG1101L (high accuracy) applies to output
only due to limitation of 3-1/2 digit display.
4 digit range. All others 3-1/2 digit
*
Accuracy
Includes linearity, hysteresis, repeatability
DPG1000L, DPG1100L: ±0.25% of full scale ±1 LSD
DPG1001L, DPG1101L: ±0.1% of full scale ±1 LSD
±0.1% accuracy not available with 3 psig, 5 psig, absolute,
vacuum, or bipolar ranges
Sensor hysteresis:
±0.015% FS, included in accuracy
Sensor repeatability: ±0.01% FS, included in accuracy
Low voltage
indicator
88888
X X X X X
TEST
s
OMEGA Engineering Inc. / Made in USA
¼" NPT
3.38" Standard
3.5" NEMA 4X
Ranges >2000
TM
4-20 mA Loop Powered
4-20 mA Loop Powered, High Accuracy
4-20 mA Loop Powered, NEMA 4X
4-20 mA Loop Powered, High Accuracy, NEMA 4X
Display
Resolution is fixed. Some ranges may not use all display digits.
Ranges to 1999: 3-1/2 digit LCD, 1/2" digit height
Ranges >2000: 4 digit LCD, 0.4" digit height with 5 character
Power
Any DC supply/loop resistance that maintains 8-32 VDC at
gauge terminals.
May be operated as a 4-20 mA loop transmitter or a DC pow-
ered pressure indicator.
Reverse polarity protected. Designed for continuous operation.
3 ft long, 2-conductor 22 AWG cable with stripped wire ends
Output Characteristics
Ranges to 1999: Analog output, 50 msec. typical response
Ranges 2000-up: 12,000 counts over sensor range
Low Loop Warning
Ranges to 1999:
Ranges 2000-up: All decimal points flash. Below 7.8 VDC
Test Function
TEST button, when depressed sets loop current and display
to output test level, independent of pressure input, to allow
, cmH 2 O, oz/in
.
2
2
testing of system operation.
Output test adjustment: 0-100% or range
Calibration
Ranges to 1999: Front zero, span and test potentiometers
Ranges 2000-up: User set pass code for calibration mode
Process Connection and Material
1/4" NPT male
Sensor and all wetted parts are 316L stainless steel
Potentiometer
2
covers (3)
Standard:
t
plastic caps
NEMA 4X:
nylon screws
with o-rings
0.75"
DPG1000L,
DPG1001L
3 readings/sec. nominal display update
0.25" H alphanumeric lower display
4 readings/sec. nominal display update
time
Updated approximately 16 times per second
Colon appears on display at approximately
7.8 VDC. Below 7.8 VDC erratic operation
may occur.
erratic operation may occur and gauge may
shut off.
Non-interactive zero and span, ±10% range
Internal potentiometers: Loop 4 mA and 20 mA
zero, midpoint, span as required for each range
2.88"
PSIG
TEST
Span
Test
Zero
Cecomp Electronics / Made in USA
0.75"
¼" NPT
3.38" Standard
3.5" NEMA 4X
DPG1100L,
DPG1000L,
DPG1101L
DPG1001L,
Ranges >2000
The DPG1000L/DPG1100L series is a 2-wire pressure transmit-
ter with a digital display. It is powered by the 4-20 mA current
loop and produces an analog output signal. The output is filtered
to improve noise immunity. It may also be connected to a low
voltage DC supply for use as a pressure indicator.
Ranges up to 1999 have a 3.5 digit display and true analog
output. Ranges 2000 and above are microprocessor based
and use a 4 digit display with an alphanumeric lower display.
The output is a 12,000 count analog 4-20 mA signal updated
approx. 16 times per second.
Models are designed for continuous operation. Warm-up time is
negligible. The display will show the system pressure/vacuum
and the loop current will be proportional to the system pressure/
vacuum; 4 mA = Zero or low end, 20 mA = Span, full-scale or
high end.
The TEST button, when depressed, switches the display and
output loop to a preset level determined by the setting of a Test
potentiometer. This is useful for testing the 4-20 mA output
signal without having to alter system pressure.
Housing
Standard: Epoxy powder coated aluminum case and rear
cover, ABS/polycarbonate bezel, polycarbonate label, front and
rear rubber gaskets
NEMA 4X: UV stabilized ABS/polycarbonate case and
gasketed rear cover with six captive stainless steel screws.
polycarbonate label
Weight
Gauge: 9 ounces, shipping weight: 1 pound (approximate)
Overpressure, Burst, Vacuum
3000 psig sensor: 5000 psig overpressure, 10,000 psi burst
5000 psig sensor: 7500 psig overpressure, 10,000 psi burst
All other sensors: 2 X sensor range overpressure
All other sensors: 4 X sensor range burst
>2X overpressure will permanently damage sensor
Vacuum service: ±15 psig, 15 psia, 15 psig, 30 psia, 100
psig, 100 psia, 200 psig sensors. Vacuum on all others will
permanently damage sensor
4 digit ranges (3000 psi, 5000 psi)
112.5% full scale out-of-range display: 1– – – or 1 –.–.–.–
Under-range display (non-vacuum sensors): –Err
Environmental
Storage Temperature:
Operating Temperature:
Compensated Temperature: 32 to 158°F (0 to 70°C)
3.0"
NEMA 4X
Standard
Allow 1"
clearance
Turn at hex
fitting only
2.0"
1.65"
DPG1100L,
DPG1101L,
Ranges >2000
–40 to 203°F (–40 to 95°C)
–4 to 185°F (–20 to 85°C)
3 ft long 2
conductor 22
AWG cable
with stripped
and tinned
wire ends
Allow 1"
clearance
Turn at hex
fitting only

Advertisement

loading

Summary of Contents for Omega Engineering DPG1000L

  • Page 1 Ranges >2000 For latest product manuals: www.omegamanual.info DPG1000L 4-20 mA Loop Powered The DPG1000L/DPG1100L series is a 2-wire pressure transmit- DPG1001L 4-20 mA Loop Powered, High Accuracy ter with a digital display. It is powered by the 4-20 mA current...
  • Page 2 RED + Power (+) mA meter (+) mA meter (–) DPG1000L, DPG1001L, DPG1100L, DPG1101L Series with Ranges to 1999 Test Function Calibration When the front-panel TEST button is held depressed, the display 1. See rear label of gauge for pressure range.
  • Page 3 DPG1000L, DPG1001L, DPG1100L, DPG1101L Series with Ranges 2000 and Up accurate than the gauge being calibrated. The calibration The lower display will alternate between CAL and 20 MA. system must be able to generate and measure pressure/ Use the s and t buttons to adjust the actual loop current to vacuum over the full range of the gauge.
  • Page 4 WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.

This manual is also suitable for:

Dpg1001lDpg1100lDpg1101l