IsoSplitter
DC to DC Signal Splitter/Isolator/Transmitter, Factory Configured
®
1 Input:
0-100 mV to 0-300 V, ±100 mV to ±10 V, 0-1 mA to 0-1000 mA, 4-20 mA
2 Outputs:
0-1 V to 0-10 V, optional up to 20 V, ±1 V to ±10 V, 0-1 mA to 20 mA, 4-20 mA
O One Input to Two Outputs with Full Isolation
O Zero and Span Output Calibration Potentiometers
O Full 1200 V Input/Output /Power Isolation
O Output LoopTracker
LEDs
®
O Output Test/Manual Override for Each Channel
O Built-In Loop Power Supply for Sink/Source Input
Applications
Q Split, Convert, Boost, and Rescale Process Signals
Q Split Process Signals for Control and Validation
Q Interface a Process Signal with Multiple Panel Meters,
PLCs, Recorders, Data Acq., DCS, & SCADA Systems
DC Input Range
Factory configured, please specify input range or consult fac-
tory for special ranges.
Voltage:
0-100 mVDC
to
Bipolar voltage:
±100 mVDC
to
Current:
0-1 mADC
to
Input Impedance and Burden
Voltage:
200 kΩ minimum
50 Ω typical
Current:
Voltage burden:
1.25 VDC max. at 20 mA current input
Input Loop Power Supply
15 VDC ±10%, regulated, 25 mADC
May be selectively wired for sinking or sourcing mA input
LoopTracker
Variable brightness LEDs indicate output loop level and status
One red LED for each output
Channel 1 and Channel 2 DC Output Ranges
Factory configured, please specify for each output channel
Outputs are independent and do not need to be the same
Voltage:
0-1 VDC to 0-10 VDC, 10 mA max
Up to 20 VDC with M19, M29, M39
Bipolar voltage:
±1 VDC to ±10 VDC
Current:
0-1 mADC to 0-20 mADC, 4-20 mADC
20 V compliance, 1000 Ω at 20 mA
Output Calibration
Multi-turn zero and span potentiometers for each output channel
±15% of span adjustment range typical
Output Loop Power Supplies
20 VDC nominal, regulated, 25 mADC for each output channel
May be selectively ordered for sinking mA output
Output Test/Manual Override
Terminals for customer-supplied external contacts to manu-
ally set output levels for each channel
Output test level factory set to 50 % of span
Specify if special output percentage levels are required
Output Ripple and Noise
Less than 10 mV
ripple and noise
RMS
Linearity
Better than ±0.1% of span
Ambient Temperature Range and Stability
–10°C to +60°C operating ambient
Better than ±0.04% of span per °C stability
Response Time
70 milliseconds nominal
Isolation
Full 4-way, 1200 V
minimum
RMS
Installation Environment
IP 40, requires installation in panel or enclosure with ade-
quate ventilation
For use in Pollution Degree 2 Environment
Mount vertically (as shown in picture) to a 35 mm DIN rail
allowing minimum 1" (25 mm) above and below housing
vents for air circulation
Power
85-265 VAC, 50/60 Hz or 60-300 VDC, 6 W maximum
D versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 6 W maximum
Dimensions and Connectors
0.89" W x 4.62" H x 4.81" D
22.5 mm W x 117 mm H x 122 mm D
Four 4-terminal removable connectors, 14 AWG max wire size
A
A
P
P
BSOLUTE
BSOLUTE
ROCESS
ROCESS
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
Made in USA
Applications Link
0-300 VDC
api-usa.com/apps
±10 VDC
0-1000 mADC
Free Factory
I/O Setup!
Description
The APD 4930 IsoSplitter accepts a DC voltage or current
input and provides two optically isolated DC voltage or current
outputs that are linearly related to the input. The input range
and each output range are independent and can be specified as
required. This provides an economical solution when one signal
must be sent to two different devices.
Typical applications include isolation, output splitting, output
device separation and redundancy (i.e. to prevent failure of
the entire loop if one device fails), or a combination of these.
The input signal is filtered, amplified, split, and then passed
through an opto-coupler to the output stages. Full 4-way isola-
tion (input, output 1, output 2, power) make this module useful
for ground loop elimination, common mode signal rejection,
and noise pickup reduction.
Model
APD 4930
APD 4930 D
Options—add to end of model number
M19
Channel 1 high voltage output (>10 to 20 VDC max.)
M29
Channel 2 high voltage output (>10 to 20 VDC max.)
M39
Channel 1 and channel 2 high voltage output (>10 to
20 VDC max.)
EXT1 Sinking mA output channel 1
EXT2 Sinking mA output channel 2
EXT3 Sinking mA output channel 1 and 2
U
Conformal coating for moisture resistance
I
I
NSTRUMENTS
NSTRUMENTS
Custom I/O Ranges
5 6 7 8
DC Input: Voltage or
Sink/Source mA
Output LoopTracker
LED
Zero and Span for
Each Output
2 Output Channels;
Voltage or mA with
Sink or Source Options
9 10 11 12
Pb
Lead
Universal
Free
Power
Input
Factory configured
specify output ranges and type for
specify input range and type
1220 American Way Libertyville, IL 60048
Phone:
800-942-0315
APD 4930
Quick Link:
1 2 3 4
13 14 15 16
Independent Outputs
Each output channel is factory ranged to your specifications
and provides an optically isolated DC voltage or current output
that is linearly related to the input. Sourcing mA outputs are
standard. Sinking milliamp or high voltage outputs are optional.
Isolation
The full 4-way (input, output 1, output 2, power) isolation
makes this module useful for ground loop elimination, common
mode signal rejection or noise pickup reduction.
LoopTracker
API exclusive features include two LoopTracker LEDs (one for
each output channel) that vary in intensity with changes in the
process output signals. These provide a quick visual picture of
your process loop at all times and can greatly aid in saving time
during initial startup and/or troubleshooting.
Output
Factory configured
85-265 VAC or 60-300 VDC
9-30 VDC or 10-32 VAC
channel 1 and channel 2
Accessory—order as separate line item
API BP4 Spare 4-terminal plug, black
api-usa.com
Fax: 800-949-7502
api-usa.com/4930
Removable Plugs
See Wiring
Diagrams on
Next Page
Power
© 08-20

Advertisement

loading

Summary of Contents for Absolute Process Instruments IsoSplitter APD 4930

  • Page 1 IsoSplitter DC to DC Signal Splitter/Isolator/Transmitter, Factory Configured APD 4930 ® 1 Input: 0-100 mV to 0-300 V, ±100 mV to ±10 V, 0-1 mA to 0-1000 mA, 4-20 mA Quick Link: api-usa.com/4930 2 Outputs: 0-1 V to 0-10 V, optional up to 20 V, ±1 V to ±10 V, 0-1 mA to 20 mA, 4-20 mA O One Input to Two Outputs with Full Isolation O Zero and Span Output Calibration Potentiometers 1 2 3 4...
  • Page 2 Installation and Setup APD 4930  * Do not make Precautions Calibration Voltage connections to WARNING! All wiring must be performed by a qualified electri- Input and output ranges are pre-configured at the factory (at Xmtr unused terminals! cian or instrumentation engineer. See diagram for terminal 24°C ±1°C) as specified on your order.

This manual is also suitable for:

Isosplitter apd 4930 d