Manual installation Veko Sensor
1
4
7
9
This page applies to all MD-L subtypes and config-
urations.
1 Switch off the power supply before connecting the
light system.
2 Example of a sensor. Note: Sensor type
and/or linear lighting profile may vary.
3 Ensure correct position of poles and wiring.
Manual Veko linear lighting system / V20 / 2021-02
2
5
Technical data
Power (W)
Voltage (V)
Length (mm)
Frequency (Hz)
Circuit
Sensitivity settings
Twilight circuit
Switch-off delay relay
Environment application
Corridor function / dynamic switch
(example: 10-100 %)
Programming
ENEC certification
Warranty
8
MD-L-R
- Length -
- Width -
Plug the connector into the flat cable.
5 Press and attach the safety clip for
emergencies in the continuous-row
lighting profile.
6 Install the sensor in the profile.
7 In the case of the Narrow lens, a cover
can be used to limit the range of the
3
6
1,5 W < 4 W (Switched off- < on)
220-240 V
300 mm
50 ÷ 60 Hz
6 A
5 (standard max. sensitivity)
Adjustable in 9 steps 0-1.000 Lux
Relay 0-99 minutes
-25 °C - + 35 °C
In combination with DALI driver
and control gear
Readout and re-programmable by
colour coding with LED in sensor
In application at DEKRA
5 years
MD-L-N
sensor, if necessary. This cover can be cut to size
with pliers or scissors on the break line to achieve
the desired range and angle of the sensor.
8 Technical data.
9 Sensor range:
MD-L-R (round lens)
MD-L-N (narrow lens)
10/18

Advertisement

loading

Summary of Contents for Veko MD-L-R

  • Page 1 7 In the case of the Narrow lens, a cover MD-L-R (round lens) 3 Ensure correct position of poles and wiring. can be used to limit the range of the MD-L-N (narrow lens) Manual Veko linear lighting system / V20 / 2021-02 10/18...
  • Page 2 Manual configuration MD-L-R / MD-L-N When the MD-L-R / MD-L-N is plugged into the light line and connected to power, it will fully function and perform as a motion detection sensor. All Veko sensors have a standard configuration. Some of these features are manual adjustable with a remote control TR67 (TR67).