Download Print this page
Panasonic FD-F41Y Instruction Manual
Panasonic FD-F41Y Instruction Manual

Panasonic FD-F41Y Instruction Manual

Liquid level detection (liquid-contactable type)

Advertisement

Quick Links

/LTXLG /HYHO 'HWHFWLRQ /LTXLGFRQWDFWDEOH 7\SH
FD-F41Y, FD-HF40Y
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly for the correct
and optimum use of this product.
.LQGO\ NHHS WKLV PDQXDO LQ D FRQYHQLHQW SODFH IRU TXLFN UHIHUHQFH
For details of fiber amplifiers, refer to the instruction manual enclosed
ZLWK HDFK ¿EHU DPSOL¿HU
1
PREPARING PROTECTIVE TUBE
Cutting off the protective tube
0DNH VXUH WR FXW WKH SURWHFWLYH WXEH E\ XVLQJ WKH ¿EHU FXWWHU FX-CT3. Do
QRW FXW WKH SURWHFWLYH WXEH E\ XVLQJ RWKHU WKDQ WKH ¿EHU FXWWHU VLQFH WKH
¿EHU PD\ JHW VFUDWFKHG
Impossible cutting range of the protec-
tive tube is 50mm from the tip of the
protective tube.
<How to cut>
1. Insert the protective tube into "ø4
78%(´ VLGH RI WKH ¿EHU FXWWHU
Find desired cutting point by using the
blade recess as a indicator.
 :KLOH SUHVVLQJ GRZQ ³$´ SDUW RI WKH
¿EHU FXWWHU DQG WXUQ WKH SURWHFWLYH WXEH
once.
The protective tube is cut.
Extending the protective tube
In case of extending the protective tube, use the protective tube extend-
ing joint MS-FX-02Y RSWLRQDO 
3OHDVH VHSDUDWHO\ DUUDQJH D SURWHFWLYH WXEH IRU H[WHQGLQJ ¡ WKLFN-
QHVV PP DQG PDGH RI 3)$ 
<How to extend>
1. Assemble the protective tube extending
MRLQW DV VKRZQ LQ WKH ULJKW ¿JXUH
However, when tightening the union nut
on the body, keep a space so that the
protective tube can be inserted.
2. Insert the protective tube for extending
IURP WKH ¿EHU HQG
3. Insert the protective tube extending joint
IURP WKH ¿EHU WLS RU ¿EHU HQG 
4. Adjust the joint of the protective tube
with the center position of the protective
tube extending joint. Tighten the union
nut by hand till it is firmly fixed, then
slowly further tighten the nut one and a
half turns by using a wrench.
INSTRUCTION MANUAL
0-()')< 1R9
Impossible cutting
range: 50mm
Fiber cutter
FX-CT3
Protective tube
<Bottom view>
Blade recess
³$´ SDUW
Union nut
)HUUXOH ZKLWH
Body
)HUUXOH ZKLWH
Union nut
Protective tube for
extending
3OHDVH DUUDQJH VHSDUDWHO\
Protective tube
Protective tube for
extending
Protective tube
Union nut
Union nut
2
MOUNTING ON A TANK
When mounting this product on a tank,
XVH WKH ¿EHU PRXQWLQJ MRLQW MS-FX-03Y
RSWLRQDO RU WKH IROORZLQJ UHFRPPHQG-
ed product.
Mount the product on a tank under the
condition that a pressure is not applied
to the tank and the liquid temperature
is between -10 to +40°C.
<Recommended products>
1,3321 3,//$5 3$&.,1* &R /WG
Flowell Co., Ltd.
Note: For details of the recommended products, contact the each manufacturers.
<How to mount>
1. Assemble the fiber mounting joint as
VKRZQ LQ WKH ULJKW ¿JXUH
However, when tightening the union nut
on the body, keep a space so that the
protective tube can be inserted.
 ,QVHUW WKH ¿EHU PRXQWLQJ MRLQW IURP WKH
¿EHU WLS RU ¿EHU HQG 
 7LJKWHQ WKH XQLRQ QXW RI WKH ¿EHU PRXQW-
ing joint at the desired point by hand
till it is firmly fixed, then slowly further
tighten the nut one and a half turns by
using a wrench.
4. Wind a sealing tape on the tank attach-
ing potion of the fiber mounting joint,
then mount on the tank. Tighten the
ERG\ RI WKH ¿EHU PRXQWLQJ MRLQW E\ XVLQJ
a wrench.
1RWH 'R QRW PRXQW WKH SURGXFW RQ D WDQN ZKHQ D ¿EHU DPSOL¿HU LV FRQQHFWHG WR WKH SURGXFW
,I WKH ¿EHUV DUH WZLVWHG WKH VHQVLQJ SHUIRUPDQFH PD\ GHWHULRUDWH RU PD\ FDXVH WKH
¿EHU EUHDN 7DNH FDUH WKDW D ¿EHU DPSOL¿HU PD\ DOVR EUHDN
3
MOUNTING OF FIBER ATTACHMENT
Mount the fiber attachment FX-AT4 DFFHVVRU\ RQ WKLV SURGXFW EHIRUH
FRQQHFWLQJ WR D ¿EHU DPSOL¿HU 7KHUH LV QR GLIIHUHQFH EHWZHHQ HPLVVLRQ
¿EHU DQG UHFHSWLRQ ¿EHU ZKHQ PRXQWLQJ WKHP RQ WKH ¿EHU DWWDFKPHQW
7KLV SURGXFW PXVW EH FXW ZLWK WKH ¿EHU FXWWHU FX-CT3 before insertion into
WKH ¿EHU DPSOL¿HU
:KHQ FXWWLQJ RII WKH ¿EHU FDEOHV HQGV PP RU PRUH FDEOHV IURP WKH HQG
of the protective tube should be left with the fiber attachment mounted.
However, in case of mounting a liquid preventive joint MS-FX-01Y RSWLRQDO 
30mm or more cables from the liquid preventive joint is required.
Take care that the sensing performance may deteriorate depending on
WKH FXWWLQJ FRQGLWLRQ RI WKH ¿EHU FDEOHV HQGV
<How to mount>
1. Mount the holder on the gland lightly.
2. Insert the fiber cables into the holder
LQ WKH VWHS  DQG SXVK WKH ¿EHUV RXW WLOO
the desired length is reached.
3. Tighten the holder.
4. Insert the fiber cables into the holes
³¡   ),%(5´ RQ WKH ¿EHU FXWWHU ZLWK
keeping the condition in the step 3.
Insert the fiber cables till the fiber at-
tachment stops.
 6OLGH ³$´ SDUW RI WKH ¿EHU FXWWHU GRZQ WR
FXW WKH WZR ¿EHUV VLPXOWDQHRXVO\
7KH ¿EHUV ZLOO EH FXW DW D SRVLWLRQ DS-
prox. 0.5mm from the holder tip.
6. $IWHU FXWWLQJ RII WKH ¿EHU FDEOHV FRQQHFW
WKHP WR WKH ¿EHU DPSOL¿HU LPPHGLDWHO\
1RWHV  7KH ¿EHUV VKRXOG EH FXW LQ RQH VWURNH
 7KH ¿EHU FXWWHU FDQ FXW WKH ¿EHU XQWLO  WLPHV 8VLQJ WKH ¿EHU FXWWHU ZKLFK LV XVHG
more than 10 times makes the cut surface worth and the sensing performance de-
teriorate.
 7KH EODGH FDQQRW EH UHSODFHG 3OHDVH SXUFKDVH DQ DGGLWLRQDO ¿EHU FXWWHU LI UHTXLUHG
 6LQFH D EODGH LV XVHG LQ WKH ¿EHU FXWWHU WDNH VXI¿FLHQW FDUH ZKHQ XVLQJ LW
 FX-CT3 LV WKH H[FOXVLYH ¿EHU FXWWHU IRU FD-F41Y and FD-HF40Y. Do not use it for
other fibers.
Fiber mounting joint
MS-FX-03Y 2SWLRQDO
Union nut
)HUUXOH ZKLWH
Body
Protective tube
7DQN DWWDFKLQJ SRUWLRQ 5
Union nut
Tank
30mm or
Possible cutting
more
range
Protective tube
Fiber
Holder
*ODQG
Fiber
$W GHVLUHG OHQJWK
Fiber cutter
FX-CT3
³$´ SDUW