1
SPECIFICATIONS
PFA mounting bracket type (For screw-fixing)
Type
3m cable length type
NPN output type
Model
Item
No.
PNP output type
Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. (Note1, 2)
Sensing object
Supply voltage
Current consumption
<NPN output type>
NPN open-collector transister
Maximum sink current: 50mA
Output
Applied voltage: 30V DC or less (between output and 0V)
Residual voltage: 1.0V or less (at 50mA sink current)
Output operation
ON when normal operation, OFF when leak is detected or the sensor is mounted improperly.
Short-circuit protection
Response time
Abnormality indicator
Normal indicator
Protection
Ambient temperature
Ambient humidity
Ambient illuminance
Emitting element
Material
0.1mm
Cable
cabtyre cable, 3m long
Weight
Accessories
Notes: 1)
Highly viscous liquid may not be stably detected.
2)
The agents mentioned above are examples. Further, PVC mounting bracket may not be used
depending on type or viscosity etc. of the agent. For details, please contact us.
3)
Liquid being detected should be also kept within the rated ambient temperature range.
4)
The specified ambient temperature is only for fixed product.
2
CAUTIONS
This product has been developed / produced for industrial use only.
Avoid using the product in an explosive atmosphere because this
product does not have an explosive-proof protective construction.
Make sure to carry out the wiring in the power supply off condition.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
Take care that if a voltage exceeding the rated range is applied, or if
an AC power supply is directly connected, the sensor may get burnt
or damaged.
If power is supplied from a commercial switching regulator, ensure that the
frame ground (F.G.) terminal of the power supply is connected to an actual
ground.
Do not use during the initial transient time (50m sec. approx.)
after the power supply is switched on.
In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this product, connect the frame
ground (F.G.) terminal of the equipment to an actual ground.
Cable extension is possible up to total 50m with 0.3mm
However, in order to reduce noise, make the wiring as short as possible.
Do not run the wires together with high-voltage lines or power lines or put
them in the same race way. This can cause malfunction due to induction.
In case a surge is generated in the used power supply, connect a
surge absoeber to the supply.
Ramco National
INSTRUCTION
MANUAL
MJEC-EXF60 No.0045-90V
5m cable length type
EX-F61
EX-F61-C5
EX-F61-PN
EX-F61-PN-C5
12 to 24V DC
0.4V or less (at 16mA sink current)
Red LED (lights up when leak is detected or the sensor is mounted improperly.)
Green LED (lights up when the sensor is mounted properly.)
-10 to +60
(No dew condensation or icing allowed) (Note 3, 4), Storage: -20 to +70
35 to 85% RH, Storage: 5 to 85% RH
Incandescent light: 1,000 lx or less at the light-receiving face
2
2
3-core PFA
0.1mm
cabtyre cable, 5m long
60g approx.
80g approx.
PFA mounting bracket: 1 pc.
2
, or more, cable.
800-280-6933 | nsales@ramcoi.com
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly
for the correct and optimum use of this product. Kindly keep
this manual in a convenient place for quick reference.
This product is a sensor for detecting leak of
fluids.
When this product is used with safety devices,
construct the system such that the device itself
WARNING
always operates in the safety side.
PVC mounting bracket type (For adhesive-fixing)
3m cable length type
EX-F62
EX-F62-PN
10% Ripple P-P 10% or less
15mA or less
<PNP output type>
PNP open-collector transister
Maximum source current: 50mA
Applied voltage: 30V DC or less (between output and +V)
Residual voltage: 1.0V or less (at 50mA source current)
Incorporated
50ms or less
IP67(IEC)
Infrared LED (non-modulated)
Enclosure: PFA
2
3-core PFA
0.1mm
3-core PFA
cabtyre cable, 3m long
60g approx.
PVC mounting bracket: 1pc.
Be sure to use the exclusive mounting bracket when installing the
sensor to avoid human error, etc. Reliable detection cannot be
guaranteed when this mounting bracket is not used.
Make sure to use an isolation transformer for the DC power supply. If
an auto-transformer (single winding transformer) is used, this product
or the power supply may get damaged.
In case air bubbles are drawn into the sensing part, take care that it may take
some time for sensing to stabilize, or sensing may even become unstable.
When liquid remains on the sensing surface after leak detection, wipe all
liquid from the sensing surface. To avoid scratching the sensing surface
and the enclosed mounting bracket, use a soft cloth.
If there is liquid remained or scratch on the sensing surface or the
exclsive mounting bracket, normal operation cannot be performed.
Since this sensor employs non-modulated infrared LED, take sufficient care against
extraneous light. Do not expose the sensing part directly to the extraneous light.
Avoid dust, dirt, and steam. Further, do not use this product where oil or
grease splashes to the product, or in an environment containing corrosive gas,
etc.
In case this sensor is used where electrostatic charge is present, use a
metal leak pan, which should be connected to an actual ground.
In case of using this product 50℃ or more, be sure to fix this product with
a dedicated mounting bracket.
5m cable length type
EX-F62-C5
EX-F62-PN-C5
0.4V or less (at 16mA source current)
2
0.1mm
3-core PFA
cabtyre cable, 5m long
80g approx.
www.panasonicsensors.com
3
M
EX-F6
Ins
(len
we
fac
hol
bra
M4
sep
torq
less
EX-F6
Ple
sur
sen
Use
How to
Alig
the
How to
Pin
upw
Nev
4
I/
NP
Inte

Advertisement

loading

Summary of Contents for Panasonic EX-F60 Series

  • Page 1 Thank you very much for purchasing Panasonic products. INSTRUCTION Please read this Instruction Manual carefully and thoroughly MANUAL for the correct and optimum use of this product. Kindly keep EX-F6 this manual in a convenient place for quick reference. Amplifier Built-in Leak Detection Sensor...
  • Page 2 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan nt, use a Phone: +81-568-33-7861 FAX: +81-568-33-8591 About our sale network, please visit our website. duct with © Panasonic Industrial Devices SUNX Co., Ltd. 2014 PRINTED IN JAPAN Ramco National 800-280-6933 | nsales@ramcoi.com www.panasonicsensors.com...

This manual is also suitable for:

Ex-f61Ex-f61-c5Ex-f62Ex-f62-c5Ex-f61-pnEx-f61-pn-c5 ... Show all