Quick Links

IS-6520S-GE/SE Installation Guide
Shipping List
2 PIN Terminal Block
Cables (6)
Plastic Conical Anchor (4)
Bracket
IS-6520S-GE/SE
Quick Start Guide
(Note: There are 6 cables including two 4 PIN cables, one 5 PIN cable, one 9 PIN cable, one 7 PIN cable, and one 12 PIN
cable.)
Contact the local authorized Honeywell representative if anything is missing.
Introduction
This installation guide introduces how to install IS-6520S-GE/SE. Refer to User Guide for how to operate IS-6520S-GE/SE.
Product Dimension
Installation
Note the following items before mounting:
If the sensor is normally open, a
If the sensor is normally
2 kΩ EOL resistor must be wired in
closed, a 2 kΩ EOL
parallel with the sensor. The EOL
resistor must be wired in
resistor must be near the sensor.
series with the sensor.
Cut off the power supply before mounting.
Deepened 86 Gang Box is recommended.
Perform the following steps to mount IS-6520S-GE/SE.
1.
Mark mounting holes with a bracket or a leveling instrument.
Mark mounting holes with the bracket.
Place the bracket on the 86 Gang Box and keep the arrow upward. Align the point of the left and right arrow
to the left and right inside line of 86 Gang Box respectively. Mark the 4 mounting holes on the wall with a
pencil.
Align this point to the
inside line of 86 Gang Box
Keep the arrow upward
Mark mounting holes with the leveling instrument (not included in the shipping list).
Put the leveling instrument against the wall and ensure the 86 Gang Box is aligned with 86 Gang Box frame
of the instrument. Adjust the leveling instrument until the bubble is in the center of the bubble level. Then
mark the 4 mounting holes with a pencil.
bubble level
bubble (keep the bubble in the center of the marked line)
86 Gang Box frame
2.
Drill a hole on each marked place and insert the plastic conical anchors into the holes with a hammer.
3.
Insert the self-tapping screws through the bracket and then insert them into the plastic conical anchors. Fasten the
self-tapping screws to fix the bracket to the wall.
4.
Wire the P3, P4, P5, P6, P7, P8 cables and J4 terminal block with the external cables by referring to the following
figures.
Self-tapping Screw (4)
Installation Guide
Follow this
Follow this wiring
wiring diagram
diagram to connect the
to connect to
Fire sensor and the
the Gas
Emergency button.
sensor.
(Note: Relay 1: control the lock; Relay 2: call the elevator; Relay 3:
elevator authorization. )
5.
Insert the P3, P4, P5, P6, P7, P8 cables, the Ethernet network cable (insert into J6 port) and the J4 terminal block
into the corresponding ports on the rear panel (see the following figure).
6.
Hang the IS-6520S-GE/SE on the hooks of the bracket via the four slotted holes on the back of its housing.
Since J4 terminal block is connected to the power supply, make the J4 connection last.
IS-6520S-G/S 安装指南
装箱清单
2 PIN 接线端子
线缆(6 根)
膨胀螺丝管(4 个)
IS-6520S-G/S
挂架
快速使用指南
(注:共六根线缆,其中 2 根 4 芯线、1 根 5 芯线、1 根 9 芯线、1 根 7 芯线、1 根 12 芯线。)
拆封时,若发现零件缺失,请及时与经销商联系。
概述
本安装指南适用于安装 IS-6520S-G/S 主机。IS-6520S-G/S 主机的具体操作参考用户手册。
产品尺寸
安装
安装前注意事项:
若探测器类型为常开
若探测器类型为常闭
按以下方式连接煤气
型,需在探测器侧并联
型,回路中需串联一
探测器。
一个 2 kΩ 的电阻。
个 2 kΩ 的电阻。
安装前请切断主机供电电源。
推荐使用加深型 86 盒。
按如下步骤安装:
1.
使用挂架或水平定位仪标识安装孔。
使用挂架标识
将挂架的左侧或右侧箭头顶点对准 86 盒左侧或右侧的内侧边缘,箭头朝上放置挂架,在挂架的 4 个安装孔处
做标识。
箭头顶点对准
86 盒内侧边缘
箭头朝上放置挂架
使用水平定位仪标识(水平定位仪不随本机提供)
将水平定位仪贴紧墙壁,使 86 盒定位框对准 86 盒。调整水平定位仪的位置,使气泡位于水准泡正中间,然后
在水平定位仪的 4 个安装孔处做标识。
水准泡
气泡(使气泡处于水准泡中间的两条线之间)
86 盒定位框
2.
在标识的位置钻 4 个孔,然后敲入膨胀螺丝管。
自攻螺丝(4 个)
安装指南
按以下方式连接火灾
探测器和紧急按钮。

Advertisement

loading

Summary of Contents for Honeywell IS-6520S-GE

  • Page 1 在水平定位仪的 4 个安装孔处做标识。 bubble level bubble (keep the bubble in the center of the marked line) Hang the IS-6520S-GE/SE on the hooks of the bracket via the four slotted holes on the back of its housing. 水准泡 气泡(使气泡处于水准泡中间的两条线之间) 86 Gang Box frame Drill a hole on each marked place and insert the plastic conical anchors into the holes with a hammer.
  • Page 2 FAX +86 21 62370740 亚太区总部 86 盒定位框 中国上海市遵义路 100 号虹桥上海城 A 座 35 楼 在標識的位置鑽 4 個孔,然后敲入膨脹螺絲管。 电话:(86)21-22196888 传真:(86)21-62370740 亞太區總部 中國上海市遵義路 100 號虹橋上海城 A 座 35 樓 電話:(86)21-22196888 傳真:(86)21-62370740 http://www.security.honeywell.com http://www.cn.security.honeywell.com ©2014 Honeywell International Inc. All rights reserved. Document 800-18852 Rev.A...