INSTALLATION INSTRUCTIONS

HID WALL PACK
E-WPG1
E-WPG2

IMPORTANT SAFEGUARDS

Error!
1. RISK OF FIRE AND ELECTRICAL SHOCK. THIS
PRODUCT IS TO BE INSTALLED BY A QUALIFIED
ELECTRICIAN ONLY.
2. To avoid the possibility of electrical shock, turn off power
supply before installation or service.
INSTALLATION OF MOUNTING BOX
1. This carton contains fixture, lamp, and wall mounting box.
2. Review template on backside of installation sheet.
NOTE: Template includes minimum mounting distance to
ceilings.
3. Place mounting box over junction box or conduit. If mounting
over junction box, a 2-1/2" inspection hole knockout is
included. See Figure 1.
FIGURE 1
4. For surface wiring (3) 1/2" threaded holes are available. See
Figure 1.
5. IMPORTANT – Keyholes located inside box are for
alignment only. Fixture is to be supported by (3) 3/16"
Document:
Created by: TMT
E-WPC1
E-WPC2
CI308X51R0
Date: 2/1/2013
DCR#:
mounting holes. Recess surrounding mounting hole will
accommodate a 1/4" bolt head. Select appropriate mounting
hardware for mounting surface.
6. Place a minimum of a 1/4" bead of silicone rubber on black
gasket on back of mounting box. See Figure 1a.
FIGURE 1a
7. Before securing fixture to wall mounting surface, make sure
mounting box is level.
8. Secure mounting box to wall.
INSTALLATION OF FIXTURE
1. Loosen (2) phillips lens screws located on the bottom of lens.
Lift lens up and remove from fixture.
2. Loosen (2) torx screws (use 1/4" nut driver or T-20 torx) and
remove junction box cover.
3. If mounting fixture over surface mounted conduit, knockout
conduit opening on either the top or sides as required. See
Figure 2. Knockouts can be removed by using a hammer or
pliers.
4. Place fixture on mounting box making sure that screws on
mounting box insert through keyhole opening on fixture.
5. Tighten torx screws use a T-20 torx or 1/4" nut driver.
6. See electrical connection instructions.
7. Screw supplied lamp into socket.
8. Replace glass lens by hooking hinge on top of casting and
allowing lens to close. Tighten (2) phillips screws.
FIGURE 2
2012-071

Advertisement

loading

Summary of Contents for e-conolight E-WPG1

  • Page 1: Installation Instructions

    See Figure 1a. FIGURE 1a 7. Before securing fixture to wall mounting surface, make sure mounting box is level. 8. Secure mounting box to wall. E-WPG1 E-WPC1 INSTALLATION OF FIXTURE E-WPG2 E-WPC2 1. Loosen (2) phillips lens screws located on the bottom of lens.
  • Page 2 INSTALLATION INSTRUCTIONS Document: CI308X51R0 Date: 2/1/2013 2012-071 HID WALL PACK Created by: TMT DCR#: ELECTRICAL CONNECTIONS CONNECTING INCOMING POWER: 1. Connect the green with yellow leads from mounting box and fixture to the incoming ground. WARNING – To avoid the possibility of electrical shock; turn 2.