$33/,&$7,21
The MF4000A, MF4000P and MF4000B are servo motors to
control and govern airlock of gaseous and liquid fuels or to
action the VF5000 series butterfly valves.
These servo motors are suitable in burners with medium to
high capacity.
63(&,),&$7,216
0RGHOV
MF4000A1 series to drive air dampers and VF5000 butterfly
valves, with floating adjustment (see Figure 2.).
MF4000P1 series to drive air dampers and VF5000 butterfly
valves, with floating adjustment, with one or two feed-back
potentiometers (see Figure 2.).
MF4000B1 series to drive air dampers and VF5000 butterfly
valves, with internal relay for ON/OFF adjustment (see Figure
3.).
'LPHQVLRQV
See Fig. 1. Installation drawing MF4000 on page 2.
%877(5)< 9$/9( 6(592027256
6XSSO\ YROWDJHV
Line voltage:
220 ... 240 Vac, 50/60 Hz
110 Vac, 50/60 Hz
0D[LPXP YROWDJH
Current of microswitches: 250 Vac, 10 A (ac) and 2 A (dc)
$PELHQW WHPSHUDWXUH UDQJH
-15 .... 60°C
5DWHG WRUTXH
Maximum torque at 15s rotation time over 90 degrees: 5 Nm
Maximum torque at 30s rotation time over 90 degrees: 10 Nm
Maximum torque at 60s rotation time over 90 degrees: 15 Nm
6WURNH WLPLQJ
15, 30, 60 seconds at 50 Hz.
At 60 Hz the timing is reduced with approximately 20%
0D[LPXP DGMXVWDEOH VWURNH
0 to 90 degrees.
(QFORVXUH
IP65
0LQLPXP FDPVKDIW VWHS
2 degrees (including mechanical tolerances)
(OHFWULFDO FRQQHFWLRQ
Two PG11 wiring conduits are provided in the housing.
NOTE: Do not provide strain relief according to
EN60730
)LQLVK
The servo motor is mounted in a metal housing, which can be
opened loosening 4 screws.
'HVLJQ OLIH
0RGHO
1XPEHU RI F\FOHV
All models
MF4000
Series
1
81,9(56$/ *$6 9$/9(6
0) 6(5,(6
,16758&7,21 6+((7
250.000
EN1R-0003-0003R5-IT

Advertisement

loading

Summary of Contents for Honeywell MF4000 Series

  • Page 1 ____________________________________________________________________________________________________________________________________________________________________ 81,9(56$/ *$6 9$/9(6 0) 6(5,(6 %877(5)< 9$/9( 6(592027256 ,16758&7,21 6+((7 6XSSO\ YROWDJHV Line voltage: 220 ... 240 Vac, 50/60 Hz 110 Vac, 50/60 Hz 0D[LPXP YROWDJH Current of microswitches: 250 Vac, 10 A (ac) and 2 A (dc) $PELHQW WHPSHUDWXUH UDQJH -15 ..
  • Page 2 3. When the MF4000 is used in stand alone applications, use a proper strain-relief. Fig. 1. Installation drawing MF4000 Series 0RXQWLQJ DQG RULHQWDWLRQ $GMXVWPHQW RI FDPV There are no mounting restrictions in the angle of the motor.
  • Page 3 ______________________________________________________________________________________________________________________________________ (/(&75,&$/ &211(&7,216 IMPORTANT All wiring must comply with local and national codes of practice. Ensure all valves are correctly earthed. Fig. 2. Wiring diagram MF4000A and MF4000P Fig. 3. Wiring diagram MF4000B +RQH\ZHOO 8*9 6UO CryƒvtÃ`‚ˆÃ8‚‡…‚yÃ`‚ˆ…ÃX‚…yq Via Ferrero, 16 10090 Cascine Vica - Rivoli (To) Turin, Italy Tel:...

This manual is also suitable for:

Mf4000aMf4000bMf4000p