Download Print this page

Sears 53DS900077 Installation Instructions

Duct-free systems wall mounting kit accessory size 018-060 cooling-only and heat pump units

Advertisement

Quick Links

Installation
Instructions
GENERAL
These
instructions
cover
the installation
of the accessory
wall
mounting
kit. The kit is provided
for mounting
cooling
only,
multi-split,
and
heat
pump
units
to
a wall
due
to
space
limitations.
IMPORTANT:
Read
these
installation
instructions
thoroughly
BEFORE
starting
installation.
Refer to Table 1 for kit contents
and usage.
Table
I--KIT
CONTENTS
AND USAGE
MOUNTING
KIT PART
USAGE
KIT CONTENTS*
NUMBER
53DS900077
53DS900078
All 018,024
Sizes
Plus
38HDF/538E-
F 030
38QRF/638Q-
F030
AIIElse
030 - 060
2 - Long Bracket
Section
2 - Horizontal Bracket
Section
2 - Angled Bracket
Section
6 - Wall Lag Bolts
6 - Lag Bolt Washers
6 - Wall Lag Bolt
Shields (Anchors)
4 - Mounting Feet
Bolts (1 in.)
4 - Mounting Feet
Locknuts
10 - Bracket Assy.
Locknuts
10 - Bracket Assy.
Bolts (1/2 in.)
10 - Bracket Assy.
Lockwashers
*The contents for both kits are the same: however, the items are different
sizes for specific applications.
SAFETY
CONSIDERATIONS
Installation
of this equipment
can be hazardous
due to system
pressures,
electrical
components
and equipment
location.
Only
trained,
qualified
installers
and service technicians
should install.
start
up
and
service
this
equipment.
Observe
all applicable
precautions.
Improper
installation,
adjustment,
alteration,
service,
maintenance,
or use can cause explosion,
fire. electrical
shock,
or
other
conditions
which
may
cause
personal
injury
or property
damage.
Consult
a qualified
installer,
service
agency,
or your
distributor
or branch
for information
or assistance.
The qualified
installer
or agency must use factory-authorized
kits or accessories
when modifying
this product.
Refer to the individual
instructions
packaged
with kits or accessories
when installing.
Follow all safety codes. Wear safety glasses
and work gloves.
Use
quenching
cloth
for brazing
operations.
Have
fire extinguisher
available.
Read
these
instructions
thoroughly
and
follow
all
warnings
or cautions
attached
to the unit. Consult
local building
codes
and
National
Electrical
Code
(NEC)
for
special
requirements.
Recognize
safety
information.
This
is the safety-alert
symbol
Z_.
When
you see this symbol
on the unit and in instruction
manuals,
be alert to the potential
for personal
injury.
Understand
the
signal
words
DANGER,
WARNING,
CAUTION,
and
NOTE.
These
words
are
used
with
the
safety-alert
symbol.
DANGER
identifies
the
most
serious
hazards
which
will result
in severe
personal
injury
or death.
WARNING
signifies
hazards
which
could
result
in personal
injury
or death.
CAUTION
is used to identify
unsafe
practices
which
may
result
in minor
personal
injury
or product
and
property
damage.
NOTE
is used to highlight
suggestions
which
will result in enhanced
installation,
reliability,
or operation.
ELECTRICAL
SHOCK
HAZARD
Failure
to follow
this warning
could
result
in personal
injury or death.
Before
installation,
always
check
to be sure main power
to
system
is OFE
INSTALLATION
1. Unpack
accessory
from carton.
Check
to be sure contents
are not damaged
or missing.
See Table 1.
2. Select
mounting
location
on the wall. The location
must
allow
for use of wall studs
for mounting
security.
Check
local building
codes
and building
construction
to ensure
that there is adequate
wall strength
to support
the mounted
unit. The location
must also allow for condensate
drainage
from
the unit.
Be sure this
drainage
does
not cause
a
problem
for the area beneath
the unit.
IMPORTANT:
Ensure
that the unit will be mounted
at least 6 in.
from the wall for proper
airflow. Also ensure
that there will be at
least 6 in. of airflow
clearance
on the coil end and 18 in. on the
compressor
end for service access.
IMPORTANT:
Do not drill new holes in the bracket
assembly
in
order to move the unit closer to the wall.
3. Use the enclosed
long bracket
sections
as a template
for
marking
the mounting
kit location
on the wall.
Both long
bracket
sections
must line up with the middle
and coil end
mounting
feet of the unit. See Fig. 1.

Advertisement

loading

Summary of Contents for Sears 53DS900077

  • Page 1 USAGE NUMBER 2 - Long Bracket 2 - Horizontal Bracket All 018,024 Sizes Plus 2 - Angled Bracket 53DS900077 38HDF/538E- F 030 38QRF/638Q- F030 6 - Wall Lag Bolts 6 - Lag Bolt Washers 6 - Wall Lag Bolt 4 - Mounting Feet...
  • Page 2 4.Drill6 mounting holes i n marked-off locations onthe wall.Forwood wallmounting, drill5/16-in. diameter holes. For m asonry wall m ounting, drill5/8-in. diameter holes and insert 3/8-in. steel shields (anchors). 5.Assemble the bracket sections asshown i n Fig. 2 ,using bracket assembly bolts, lockwashers and bracket assembly locknuts.
  • Page 3 HOLE MOUNTING FOOT (_1" LONG BOLT Fig. 38BN Units Only HOLE BOLT HEAD DIAGONAL BRACE INSTALL RUBBER (SHIPPED WITH 38BN UNIT) SPACER IN WALL BRACKET CHANNEL. D06008...
  • Page 4 Copyright 2006 CAC / BDP * 7310 W. Morris St. * indianapolis, IN 46231 Printed in USA. Edition Date: 05/06 Catalol_ No: IIK-53DS900-3 Replaces: 38-56Sl Manufacturer reserves the right to change_ at any time_ specifications and designs without notice and without obligations.

This manual is also suitable for: