AEJ
EJ Relay
Contact arrangement
1: 1 Form A
Contact capacity
1: 100 A (100 V)
Operating function
0: Single side stable
Coil voltage (DC)
12: 12, 24: 24
TYPES
Contact arrangement
1 Form A
Standard packing: Carton: 1 pc.; Case: 20 pcs.
RATING
1. Coil data
Pick-up voltage
Nominal coil
(at 20°C 68°F)
voltage
(Initial)
12V DC
Max. 9.0V DC
24V DC
Max. 18.0V DC
100A 100V DC
HIGH VOLTAGE RELAY
FEATURES
1. Compact and high capacity using
double contacts in series and
permanent magnet installed.
1) Nominal switching capacity (resistive
load): 100A 100V DC, Min. 10
2) Max. cut-off current: 800A 100V DC
2. Compact and lightweight for space
savings.
70mm (L) × 80mm (W) × 34mm (H)
2.756inch (L) × 3.150inch (W) ×
1.339inch (H)
3. Environmentally friendly
In consideration of the environment,
cadmium-free contacts, lead-free solder
are used.
Coil voltage
Protective construction
12V DC
Dust cover
24V DC
Drop-out voltage
Nominal coil current
(at 20°C 68°F)
[±10%] (at 20°C 68°F)
(Initial)
Min. 1.0V DC
Min. 2.0V DC
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
4
Terminal shape
Screw terminal
Coil resistance
[±10%] (at 20°C 68°F)
417mA
28.8Ω
208mA
115Ω
EJ (AEJ)
EJ RELAYS (AEJ)

TYPICAL APPLICATIONS

Quick recharging power supplies for
AGVs (automatic guided vehicle), UPS
(uninterruptible power supplies), Fuel
cell, Combined heat/power generation
system, etc.
Part No.
AEJ11012
AEJ11024
Nominal operating
Max. allowable voltage
power
(at 20°C 68°F)
(at 20°C 68°F)
5.0W
nominal voltage
5.0W
150%V of

Advertisement

loading

Summary of Contents for Panasonic EJ Relays

  • Page 1: Typical Applications

    [±10%] (at 20°C 68°F) [±10%] (at 20°C 68°F) (Initial) Min. 1.0V DC 417mA Min. 2.0V DC 208mA EJ RELAYS (AEJ) TYPICAL APPLICATIONS Quick recharging power supplies for AGVs (automatic guided vehicle), UPS (uninterruptible power supplies), Fuel cell, Combined heat/power generation system, etc.
  • Page 2 EJ (AEJ) 2. Specifications Characteristics Item Arrangement Contact voltage drop (Initial) Contact material Nominal switching capacity (resistive load) Rating Max. carrying current/short time carrying current Min. switching capacity (Reference value)* Max. cut-off current Overload opening rating Insulation resistance (Initial) Between open contacts Breakdown voltage Electrical (Initial)
  • Page 3 6. Functional shock resistance Tested sample: AEJ11012, 3 pcs. Half-wave pulse of sine wave: 11 ms Detection time: 10µs. Applied direction: 6 directions Applied cycle: Each of 3 cycles 1,000m/s 1,000m/s DIMENSIONS (Unit: mm inch) External dimensions 71.4 2.811 58.4 2.299 36.0 1.417...
  • Page 4 8. Electrical life This relay is a high-voltage direct-current switch. In its final breakdown mode, it may lose the ability to provide the proper cut-off. Therefore, do not exceed the indicated switching capacity and life.

This manual is also suitable for:

Aej11012Aej11024