HRDV 16/8 Duplex Quick Installation
Step 1: Connect cameras, peripherals
Connect up to 16
cameras, depending on
your model.
Microphone
Power supply (not shown)
with pre-amp
75 W
110 VAC 60 Hz or
RG59
230 VAC 50 Hz
autosensing
COMM
RAS (RS232)
Text Ports
(RS232)
1 GND
14
2
DTR
15
3 GND
16
4 GND
17
5
TX
18
6
DSR
19
7 GND
20
8
CTS
21
9 DCD
22 RS485 RX+
10 GND
23 RS485 RX-
11
Ri
24 RS485 TX+
12
RX
25 RS485 TX-
13 GND
Step 2: Configure the Duplex
Mandatory settings
1.
Power up the unit and wait two minutes.
2.
Enter program mode. Press MENU on the front panel, then press 1 for
User 1, followed by 1234 for the default password.
3.
Choose Easy Configurator or Menu.
a.
Use Easy Configurator to guide you through programming in 10
minutes or less, then proceed to
b.
Or use Menu for more advanced functions as follows.
4.
Set to factory default settings (MENU
Settings). Wait ten seconds.
5.
Format all (MENU
Format All).
6.
Enable user access for each user name (MENU
Password). At least one user must have Administrative access
enabled. Silent Witness recommends that you change the passwords
for each user.
7.
Set the clock (MENU
8.
Configure camera setup (MENU
This assumes all live cameras are physically connected. Perform an
autodetect. This enables the connected cameras and automatically
adds them to the switcher.
Edit text/screen titles and numerical values
Select the line, then press Enter.
If the field is numerical, use the cursor controls
or inner jog wheel to adjust the value.
Press to move cursor up or to increase
numerical values by 1.
Press to
Use the inner jog
move left.
wheel to rapidly
increase or
decrease a
numerical value.
Press to move cursor down or to
decrease numerical values by 1.
9.
Set event drive partition to ___ %, timelapse to ____ % (MENU
Storage Setup
Event space is required to record motion, text, or alarm event clips.
10. Enable Autorecord (MENU
For more detailed information, refer to the HRDV Duplex Reference Guide and the HRDV RAS
Guide on your CD and at www.honeywellvideo.com.
1 to 3 monitors
Enable in Event
Recording
General Setup.
Exception:
Record indicator
+5 VDC = Record
GND = Stopped
Alarm Inputs
To set NO/NC, see Alarms.
+5 VDC
Normally Closed (NC).
If open, alarm is
detected.
10K
Normally Open (NO).
If closed, alarm is
detected.
Detector
External to Duplex
Internal to Duplex
(Add this functionality
yourself)
ALARM I/O
Pin
Pin
1
1
IN
1
14
1
2
IN
3
15
2
3 GND
16
2
4
IN
6
17
3
5
IN
8
18
3
6*
IN
9
19*
4
7*
IN
11
20*
4
8 GND
21*
9
IN
14
22
10
IN
16
23 +5 VDC
11
24
12 OUT
1
25
13 OUT
2
* Applies to HRDV16 Duplex only.
Step 3 - Daily
Operation.
➤
System Setup
➤
➤
Storage Setup
Disk Setup and select
➤
Change
➤
Clock Setup). Enter time and select Set.
➤
➤
System Setup
Video Inputs).
If the field is a text line, use the
Text Entry screen to edit the text.
Select Accept to confirm edited text.
Press to move
right.
➤
Disk Setup). If timelapse only, set event to 0%.
➤
➤
System Setup
User Preferences).
Alarm output
+5 VDC = Alarm
GND = No Alarm
Select Advanced Setup
for normal (day) and
alternate (night) settings.
Note
Select Alternate
Setup to set alternate
IN
2
global rates.
IN
4
Global Record Rate
IN
5
Each camera RR = global RR.
÷ no. of cameras
IN
7
GND
Image Quality (Global
compression setting.)
IN
10
Higher quality = slower
IN
12
transmission and faster use of
storage space.
IN
13
IN
15
OUT
3
OUT
4
➤
MENU
➤
Default
When motion is detected, squares turn red.
Adjust the sensitivity and trigger size as
required. Start with trigger size of one dot.
Assign zones:
Camera 1-4 = zone 1-4
Set whole screen to one zone:
Camera 1-4 + FUNCTION 8
Clear all = 5 + FUNCTION 8
Clear one box = 5
Press
to exit screen.
➤
Set event calendars (MENU
Set timelapse settings
➤
MENU
System Setup
Timelapse Recording
Select Simple Setup for single 24/7
recording.
Note
Record times
are approximate.
Set event settings
➤
Event Recording
General/Motion/Text/Alarm/Pre-Event.
Motion
Text
First, set up text ports (MENU
➤
Setup
Text Ports).
➤
➤
Event Recording
Motion / Text / Event Calendars).
For Front Panel Operation, see over.
➤
Green with numbers = recording
enabled.
Red = recording disabled.
Select Advanced Setup to
set Normal vs. Alternate
schedules.
Normal (day) = Green with numbers
Alternate (night) = red
Alarm
➤
System
Inputs
If Alarm homing is enabled
(V2.00 and later), when an
alarm is detected, the enabled
camera displays on the
monitor.
Configure pre-event settings
➤
➤
(MENU
Event Recording
Pre-event Setup).